Epson Stylus 400 User Manual - Page 81

Default settings, Appendix A-11

Page 81 highlights

Software lnltlallzatlon Control panel lnltiallzatlon L * Software sends the ESC @ (Inltlalize the printer) command. The following condition then results: 1) The prlnt buffer is cleared. 2) The defautt values are set. (The last panel settings are maintained.) * Hold down the Alt button and press the Load/Eject button. The following resuits: 1) The printer mechanism Is inltlallzed. 2) The Input data buffer is cleared. 3) The download character set is cleared. 4) The print buffer is cleared. 5) The default values are set. (The last panel settings are kept.) Default settings The table below shows the default settings that take effect when the printer is initialized. Item Default sefflng Top-of-form posltion Page length Left and right margins Line spacing Character size Vertical tab positlon Horizontal tab positions Font selection Special prlntlng effects Download character set Current paper positlon Single sheets: 65 lines for A6slze paper 61 lines for letter-size paper 22 inches for manual insertion Canceiled l/6-Inch line spaclna I 10.5 point Cleared Every eight characters Last font selected on control panel Cancelled (except condensed printing) Hardware/control panel Initialization: cleared Software Inltlallzatlon: deselected onlv In addition, hardware and control panel initialization clears the data buffer. Appendix A-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

Software
lnltlallzatlon
*
Software sends the
ESC
@
(Inltlalize
the
printer) command.
The following condition then results:
1)
The
prlnt
buffer is cleared.
2)
The
defautt
values are set. (The last
panel
settings
are maintained.)
Control panel
lnltiallzatlon
*
Hold down the
Alt
button and press the
Load/Eject
button.
The
following
resuits:
1)
The
printer
mechanism Is
inltlallzed.
2)
The
Input
data buffer
is
cleared.
3)
The download character set
is
cleared.
4)
The
print
buffer is cleared.
5)
The default values are set. (The
last
panel settings are kept.)
L
Default settings
The table below shows the default settings that take effect when the
printer is initialized.
Item
Default
sefflng
Top-of-form
posltion
Page length
Current paper
positlon
Single sheets:
65
lines
for
A6slze
paper
61
lines
for
letter-size
paper
22
inches for manual
insertion
Left and right
margins
Line
spacing
Canceiled
l/6-Inch
line
spaclna
Character
size
I
10.5
point
Vertical tab
positlon
Cleared
Horizontal tab
positions
Font
selection
Every eight characters
Last font selected on control panel
Special
prlntlng
effects
Download character set
Cancelled
(except condensed printing)
Hardware/control panel
Initialization:
cleared
Software
Inltlallzatlon:
deselected
onlv
In addition, hardware and control panel initialization clears the data
buffer.
Appendix A-11