Epson Stylus Pro 4000 Professional Edition Service Manual - Page 267
Motor Assy., PG
View all Epson Stylus Pro 4000 Professional Edition manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
EPSON Stylus Pro 4000 4.2.7.3 Motor Assy., PG 1. Remove "Cover, Side, Right" (p212). 2. Peel off the acetate tape and release the tab at the lower part of the "Sheet, Ink, Stopper, C" from the U-shaped cutout of the "Frame, Base, Side, Right". (Refer to Figure 4-87.) 3. Disconnect relay connector. (Refer to Figure 4-88.) 4. Remove the acetate tape securing the harness, and release "Harness, CSIC" and "Motor Assy., PG" harness from "Duct, Air, C" hook. (Refer to Figure 4-88.) 5. Release "Motor Assy., PG" harness and "Mount Assy., Plate, Motor, ASF, SP" harness from the U-shaped cutout of the "Frame, Base, Side, Right". (Refer to Figure 4-88.) 6. Peel acetate tape and release "PG Motor" harness. (Refer to Figure 4-88.) Sheet, Ink, Stopper, C Frame, Base, Side, Right Revision B Figure 4-87. Sheet, Ink, Stopper, C Release Step 6 Motor Assy., PG Harness Step 5 Step 4 Step 3 Disassembly & Assembly Harness, CSIC Duct, Air, C Figure 4-88. Releasing the Harness Disassembly Procedures 267