Fagor 15 Inch Beverage Center User's Manual - Page 14

Reversing the Door Hinge

Page 14 highlights

The door will not close properly. 1. The appliance is not properly leveled. 2. The door was reversed and not properly installed. 3. The gasket is dirty. 4. The shelves are out of position. Display shows "E1". "E2" or "E7". The alarm sounds and the temperature display flashes. The display shows "--". 1. "E1" or "E2" indicates that the air temperature sensor is failed. 2. E7" indicates the door switch failure. Has the appliance door been open for longer than 60 seconds? If yes, close the door. If not, then the temperature has risen higher or fallen lower than the temperature that has been set. This could be due to: 1. The appliance door being opened too often. 2. The ventilation opening being covered or too dusty. 3. A lengthy interruption to the power supply. 4. A large amount of bottles has been added to the unit. 1. The display temperature is out of the range. 1. Level the appliance with the adjustable feet. 2. Check the door hinge and reassemble correctly (See Reversing the Door Hinge section on page 8). 3. Clean the door gasket. 4. Check the shelves and reposition correctly. Call for service. 1. Do not open the door more often than necessary. 2. Clear the obstructions and clean the dust. 3&4.Leave the appliance untouched for a while until the set temperature has been reached. 1. Only temperatures within the range 16~99°F/-9~37°C will be shown. If the temperature is not within this range, the icon "--" will be displayed instead. That is normal. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

The door will not
close properly.
1.
The appliance is not properly leveled.
2.
The door was reversed and not properly
installed.
3.
The gasket is dirty.
4.
The shelves are out of position.
1.
Level the appliance with the
adjustable feet.
2.
Check the door hinge and
reassemble correctly (See
Reversing the Door Hinge
section on page 8).
3.
Clean the door gasket.
4.
Check the shelves and
reposition correctly.
Display shows “E1”.
“E2” or “E7”.
1.
“E1” or “E2” indicates that the air temperature
sensor is failed.
2.
E7” indicates the door switch failure.
Call for service.
The alarm sounds
and the temperature
display flashes.
Has the appliance door been open for longer than
60 seconds? If yes, close the door. If not, then the
temperature has risen higher or fallen lower than
the temperature that has been set. This could be
due to:
1. The appliance door being opened too often.
2. The ventilation opening being covered or too
dusty.
3. A lengthy interruption to the power supply.
4. A large amount of bottles has been added to
the unit.
1.
Do not open the door more often
than necessary.
2.
Clear the obstructions and clean
the dust.
3&4.Leave the appliance untouched
for a while until the set temperature
has been reached.
The display
shows “--”.
1.
The display temperature is out of the range.
1.
Only temperatures within the
range 16~99°F/-9~37°C will be
shown. If the temperature is not
within this range, the icon “--”
will be displayed instead. That is
normal.
14