Fisher and Paykel OR36SDBMX1 User Guide - Page 10

how to use the top burners

Page 10 highlights

2 Fig. 2.1 how to use the top burners GAS BURNERS (Triple-ring and Semi-rapid) Gas flow to the burners is adjusted by turning the dials (illustrated in fig. 2.1) which control the valves. Turning the dial so that the symbols printed on the dial point to the mark on the bezel achieves the following functions: Dial position Function SEMI-RAPID burner TRIPLE-RING burner OFF closed valve HI maximum rate LO minimum rate The maximum dial setting permits rapid boiling of liquids, whereas the minimum dial setting allows simmer warming of food or maintaining boiling conditions of liquids. To reduce the gas flow to minimum, rotate the dial further counter-clockwise to point the indicator towards the LO position (minimum rate). Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum and minimum dial settings. Never operate the burners with the dial set between the HI and OFF positions. Fig. 2.2 N.B. When the range is not being used, set the gas dials to their OFF positions. If the range will not be used for an extended period of time, it is recommended that the gas shut off valve in the main supply line be closed. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

10
10
how to use the top burners
2
GAS BURNERS (Triple-ring and Semi-rapid)
Gas
ow to the burners is adjusted by turning the dials (illustrated in
g. 2.1) which con-
trol the valves.
Turning the dial so that the symbols printed on the dial point to the mark on the bezel
achieves the following functions:
Dial
position
Function
SEMI-RAPID burner
TRIPLE-RING burner
closed
valve
maximum
rate
minimum
rate
The maximum dial setting permits rapid boiling of liquids, whereas the minimum dial set-
ting allows simmer warming of food or maintaining boiling conditions of liquids.
To reduce the gas
ow to minimum, rotate the dial further counter-clockwise to point the
indicator towards the
LO
position (minimum rate).
Other intermediate operating adjustments can be achieved by positioning the indicator
between the maximum and minimum dial settings. Never operate the burners with the
dial set between the
HI
and
OFF
positions.
N.B. When the range is not being used, set the gas dials to their
OFF
positions. If the range will not be used for an extended period of time, it
is recommended that the gas shut off valve in the main supply line be
closed.