Fluke 1502A-156 Product Manual - Page 15
Selecting Units, Parameter Menus, Menu Lockout
View all Fluke 1502A-156 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
6 General Operation 6 General Operation This section explains basic operation of the 1502A Thermometer. 6.1 Selecting Units Temperature can be displayed in degrees Celsius (indicated with "C"), degrees Fahrenheit (indicated with "F"), or Kelvin (indicated with "A" for absolute). The resistance of the sensor can also be displayed (indicated with "o" for ohms). Simply press the appropriate unit button, C, F, K, or Ω to select the units. 6.2 Parameter Menus Except for unit selection, all functions and operating parameters are accessed and edited within the parameter menus. There are four menus: the Probe parameter menu, Sample parameter menu, Comm (communication) parameter menu, and Cal (calibration) parameter menu. The arrangement of parameters in the menus is shown in Figure 5 on page 16. Menus are selected by pressing the Menu/Enter button followed by the appropriate menu selection button. The name of the menu will briefly appear on the display. For example, the Probe menu is selected by pressing the Menu/Enter button ("SEt?" appears on the display) followed by the C/Probe button ("ProbE" appears). Selecting the Cal menu requires that you press the Menu/Enter button then press the Ω/Exit button and hold it down for at least one second. The Probe menu contains parameters for selecting the probe characterization and setting the characterization coefficients. These parameters are explained in Section 6.4. The Sample menu contains parameters for setting the filter and excitation current. These are explained in Sections 6.5 and 6.6. The Comm menu contains communication parameters such as the serial baud rate or IEEE-488 address. These are explained in Sections 7.1 and 7.2. The Cal menu contains the calibration parameters. These are explained in Section 8.1. 6.3 Menu Lockout All menus can be locked out to prevent inadvertently changing parameters. By default, only the Cal menu is locked out. The lockout option is accessed in the Cal menu (see Section 8.1 "Accessing the Calibration Parameters"). If menus are locked out you must enter the correct password ("2051") to gain access. After you select the menu (see the previous section) the display will show "PA= 0000" and allow you to change the number to the correct password. Use the L and R buttons to move between the password digits and the U and D buttons to increase or decrease the value of a digit. Press Enter when all the digits are correct. If the password is entered correctly the first parameter in the menu will appear. 1502A Manual Rev. 952801 15 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664