Fluke 190-502/AM Manual - Page 26

Displaying an Unknown Signal with, Connect-and-View

Page 26 highlights

Fluke 190 Series II Users Manual Displaying an Unknown Signal with Connect-and-View™ The Connect-and-View feature lets the test tool display complex, unknown signals automatically. This function optimizes the position, range, time base, and triggering and assures a stable display of virtually any waveform. If the signal changes, the setup is automatically adjusted to maintain the best display result. This feature is especially useful for quickly checking several signals. To enable the Connect-and-View feature when the test tool is in MANUAL mode, do the following: 1 MANUAL Perform an Auto Set. AUTO appears at AUTO the top right of the screen, the key illumination is off. The bottom line shows the range, the time base, and the trigger information. - The waveform identifier (A) is visible on the right side of the screen, as shown in Figure 7. The input A zero icon at the left side of the screen identifies the ground level of the waveform. 2 MANUAL Press a second time to select the AUTO manual range again. MANUAL appears at the top right of the screen, the key illumination is on. Figure 7. The Screen After an Auto Set Use the light-gray RANGE, TIME and MOVE keys at the bottom of the keypad to change the view of the waveform manually. 18 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Fluke 190 Series II
Users Manual
18
Displaying an Unknown Signal with
Connect-and-View™
The Connect-and-View feature lets the test tool display
complex, unknown signals automatically. This function
optimizes the position, range, time base, and triggering
and assures a stable display of virtually any waveform. If
the signal changes, the setup is automatically adjusted to
maintain the best display result. This feature is especially
useful for quickly checking several signals.
To enable the Connect-and-View feature when the test
tool is in MANUAL mode, do the following:
1
MANUAL
AUTO
Perform an Auto Set.
AUTO
appears at
the top right of the screen, the key
illumination is off.
The bottom line shows the range, the time base, and the
trigger information.
The waveform identifier (
A
) is visible on the right side of
the screen, as shown in Figure 7. The input A zero icon
-
at the left side of the screen identifies the ground level of
the waveform.
2
MANUAL
AUTO
Press a second time to select the
manual range again.
MANUAL
appears
at the top right of the screen, the key
illumination is on.
Figure 7. The Screen After an Auto Set
Use the light-gray
RANGE
,
TIME
and
MOVE
keys at the
bottom of the keypad to change the view of the waveform
manually.