Stake Out Measurement (419D/424D), 419D 1 Value - specifications
View all Fluke 414D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Stake Out Measurement (419D/424D) A specific distance can be set in the Meter and used to mark off defined measured lengths. An example of this application is in the construction of wooden frames. See Figure 14 for more information. Note For best results, it is recommended to use the end reference point for a stake out measurement. See page 16 for more information. 14 1 2 3 0.625 m 0.625 m a 0.625 m b b a = b 1 2 3 1.012 m 0.625 m a 0.625 m b b gwo11.eps Laser Distance Meter Measurements 419D (1 Value) To find stake out distances with 1 value: 1. Push 4x. shows on the display. 2. Push and to increase and decrease the value that shows in the summary line. Note Hold the buttons down to increase the rate of change for the values. 3. Push to accept the value. The display shows the stake out distance in the summary line between the stake out point and the Meter (rear reference). 4. Move the Meter slowly along the stake out line and the distance decreases on the display. The arrows in the display indicate in which direction the Meter needs to be moved in order to achieve the defined distance. Note It the beeper feature is on, the Meter starts to beep at a distance of 0.1 m (4 in) from the next stake out point. As the Meter moves near to the stake out point, the beep changes and the arrows do not show on the display. 5. Push to stop the stake out function. 23