Stake Out Measurement (419D/424D) A specific distance can be set in the Meter and used to mark off defined measured lengths. An example of this application is in the construction of wooden frames. See Figure 14 for more information. Note For best results, it is recommended to use the end reference point for a stake out measurement. See page 16 for more information. 14 1 2 3 0.625 m 0.625 m a 0.625 m b b a = b 1 2 3 1.012 m 0.625 m a 0.625 m b b gwo11.eps Laser Distance Meter Measurements 419D (1 Value) To find stake out distances with 1 value:  1. Push  4x. shows on the display. 2. Push  and  to increase and decrease the value that shows in the summary line. Note Hold the buttons down to increase the rate of change for the values. 3. Push  to accept the value. The display shows the stake out distance in the summary line between the stake out point and the Meter (rear reference). 4. Move the Meter slowly along the stake out line and the distance decreases on the display. The arrows in the display indicate in which direction the Meter needs to be moved in order to achieve the defined distance. Note It the beeper feature is on, the Meter starts to beep at a distance of 0.1 m (4 in) from the next stake out point. As the Meter moves near to the stake out point, the beep changes and the arrows do not show on the display. 5. Push  to stop the stake out function. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Laser Distance Meter
Measurements
23
Stake Out Measurement (419D/424D)
A specific distance can be set in the Meter and used to
mark off defined measured lengths. An example of this
application is in the construction of wooden frames. See
Figure 14 for more information.
Note
For best results, it is recommended to use the
end reference point for a stake out
measurement. See page 16 for more
information.
1
2
3
a
b
b
0.625 m
0.625 m
1.012 m
1
2
3
a
b
b
a
=
b
0.625 m
0.625 m
0.625 m
14
gwo11.eps
419D (1 Value)
To find stake out distances with 1 value:
1.
Push
4x.
shows on the display.
2.
Push
and
to increase and decrease the
value that shows in the summary line.
Note
Hold the buttons down to increase the rate of
change for the values.
3.
Push
to accept the value.
The display shows the stake out distance in the
summary line between the stake out point and the
Meter (rear reference).
4.
Move the Meter slowly along the stake out line and
the distance decreases on the display.
The arrows in the display indicate in which direction
the Meter needs to be moved in order to achieve the
defined distance.
Note
It the beeper feature is on, the Meter starts to
beep at a distance of 0.1 m (4 in) from the next
stake out point. As the Meter moves near to the
stake out point, the beep changes and the
arrows do not show on the display.
5.