Fluke 725Ex FE 725ex Users Manual - Page 23

AO Bl CA DK EC FF GD HG IH JI KJ LL, Table 4. Key Functions, Description

Page 23 highlights

Getting Acquainted with the Calibrator Table 4. Key Functions No. Key Description A O Turns the power on and off. B l Selects voltage, mA, or loop power measurement functions in the upper display. Clears the switch test. See "Switch Test". Selects the pressure measurement function in the upper display. Repeated pushes cycle through C A the different pressure units. Use for pressure switch test. See "Switch Test". D K Zeros the pressure module reading. This applies to both upper and lower displays. E C Turns backlight on and off. F F Toggles between frequency and ohms measurement and sourcing functions. G D Toggles between Centigrade and Fahrenheit when in TC or RTD functions. H G Recalls a source value from memory corresponding to 100 % of span and sets it as the source value. Press and hold to store the source value as the 100 % value. I H Increments output by 25 % of span. J I Decrements output by 25 % of span. K J Recalls a source value from memory corresponding to 0 % of span and sets it as the source value. Press and hold to store the source value as the 0 % value. Cycles through : L L E Slow repeating 0 % - 100 % - 0 % ramp P Fast repeating 0 % - 100 % - 0 % ramp N Repeating 0 % - 100 % - 0 % ramp in 25 % steps 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Getting Acquainted with the Calibrator
13
Table 4. Key Functions
No.
Key
Description
A
O
Turns the power on and off.
B
l
Selects voltage, mA, or loop power measurement functions in the upper display.
Clears the switch test. See “Switch Test”.
C
A
Selects the pressure measurement function in the upper display. Repeated pushes cycle through
the different pressure units.
Use for pressure switch test. See “Switch Test”.
D
K
Zeros the pressure module reading. This applies to both upper and lower displays.
E
C
Turns backlight on and off.
F
F
Toggles between frequency and ohms measurement and sourcing functions.
G
D
Toggles between Centigrade and Fahrenheit when in TC or RTD functions.
H
G
Recalls a source value from memory corresponding to 100 % of span and sets it as the source
value. Press and hold to store the source value as the 100 % value.
I
H
Increments output by 25 % of span.
J
I
Decrements output by 25 % of span.
K
J
Recalls a source value from memory corresponding to 0 % of span and sets it as the source value.
Press and hold to store the source value as the 0 % value.
L
L
Cycles through :
E
Slow repeating 0 % - 100 % - 0 % ramp
P
Fast repeating 0 % - 100 % - 0 % ramp
N
Repeating 0 % - 100 % - 0 % ramp in 25 % steps