Fluke 87V FE 83V & 87V Users Manual - Page 53
Table 11. Model 83 AC Voltage Function Specifications, Function, Range, Resolution, Accuracy
View all Fluke 87V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Table 11. Model 83 AC Voltage Function Specifications Function Range Resolution K1 600.0 mV 0.1 mV 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 1. Below a reading of 200 counts, add 10 counts. 2. Frequency range: 1 kHz to 2.5 kHz. 50 Hz - 60 Hz ± (0.5 % + 4) ± (0.5 % + 2) ± (0.5 % + 2) ± (0.5 % + 2) ± (0.5 % + 2) Accuracy 30 Hz - 1 kHz ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4) Specifications 1 kHz - 5 kHz ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4)2 unspecified 45
Specifications
45
Table 11. Model 83 AC Voltage Function Specifications
Function
Range
Resolution
Accuracy
50 Hz - 60 Hz
30 Hz - 1 kHz
1 kHz - 5 kHz
K
1
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
±
(0.5 % + 4)
±
(0.5 % + 2)
±
(0.5 % + 2)
±
(0.5 % + 2)
±
(0.5 % + 2)
±
(1.0 % + 4)
±
(1.0 % + 4)
±
(1.0 % + 4)
±
(1.0 % + 4)
±
(1.0 % + 4)
±
(2.0 % + 4)
±
(2.0 % + 4)
±
(2.0 % + 4)
±
(2.0 % + 4)
2
unspecified
1.
Below a reading of 200 counts, add 10 counts.
2.
Frequency range:
1 kHz to 2.5 kHz.