Multimeters, Table 3. Rotary Switch Positions, Switch Position, Function
![]() |
View all Fluke 87V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Switch Position Any Position J L M N O P Q Table 3. Rotary Switch Positions Function When the Meter is turned on, the Meter model number briefly appears on the display. AC voltage measurement Press A for low pass filter (K) (87 only). DC voltage measurement 600 mV dc voltage range Press A for temperature (T) (87 only). Press E for continuity test. e Resistance measurement Press A for capacitance measurement. Diode test AC current measurements from 0 mA to 10.00 A Press A for dc current measurements, from 0 mA to 10.00 A. AC current measurements from 0 μA to 6000 μA Press A for dc current measurements from 0 μA to 6000 μA. Multimeters The Meter's Features 5
![](/manual_guide/products/fluke-87v-getting-started-guide-15404a0/11.png)
Multimeters
The Meter's Features
5
Table 3. Rotary Switch Positions
Switch Position
Function
Any Position
When the Meter is turned on, the Meter model number briefly appears on the display.
J
AC voltage measurement
Press
A
for low pass filter (
K
) (87 only).
L
DC voltage measurement
600 mV dc voltage range
M
Press
A
for temperature
(
T
)
(87 only).
N
Press
E
for continuity test.
e
Resistance measurement
Press
A
for
c
apacitance measurement.
O
Diode test
P
AC current
measurements from 0 mA to 10.00 A
Press
A
for dc current measurements, from 0 mA to 10.00 A.
Q
AC current measurements from 0
μ
A to 6000
μ
A
Press
A
for dc current measurements from 0
μ
A to 6000
μ
A.