Fluke 87V Getting Started Guide - Page 11

Multimeters, Table 3. Rotary Switch Positions, Switch Position, Function

Page 11 highlights

Switch Position Any Position J L M N O P Q Table 3. Rotary Switch Positions Function When the Meter is turned on, the Meter model number briefly appears on the display. AC voltage measurement Press A for low pass filter (K) (87 only). DC voltage measurement 600 mV dc voltage range Press A for temperature (T) (87 only). Press E for continuity test. e Resistance measurement Press A for capacitance measurement. Diode test AC current measurements from 0 mA to 10.00 A Press A for dc current measurements, from 0 mA to 10.00 A. AC current measurements from 0 μA to 6000 μA Press A for dc current measurements from 0 μA to 6000 μA. Multimeters The Meter's Features 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Multimeters
The Meter's Features
5
Table 3. Rotary Switch Positions
Switch Position
Function
Any Position
When the Meter is turned on, the Meter model number briefly appears on the display.
J
AC voltage measurement
Press
A
for low pass filter (
K
) (87 only).
L
DC voltage measurement
600 mV dc voltage range
M
Press
A
for temperature
(
T
)
(87 only).
N
Press
E
for continuity test.
e
Resistance measurement
Press
A
for
c
apacitance measurement.
O
Diode test
P
AC current
measurements from 0 mA to 10.00 A
Press
A
for dc current measurements, from 0 mA to 10.00 A.
Q
AC current measurements from 0
μ
A to 6000
μ
A
Press
A
for dc current measurements from 0
μ
A to 6000
μ
A.