Navigation through Display, Overview of Function Keys, Table 3-5. Function Keys, Function

Page 25 highlights

NORMA 4000/5000 Operators Manual Navigation through Display 1. Use the navigation keys (6) and (27) to navigate through the display and the menus. The active menu item, display, or entry field in which your cursor is located is backlit. 2. Press Esc (26) to cancel an entry without saving or to go to the next higher menu level. 3. Press Enter (14) to call up a menu or to confirm an entry made in a menu. 4. Press the measuring keys (7) and (15) to (25) to select the display mode and the save or output functions for measured values. The assignment of the function keys (9) varies, depending on the current menu. The current key assignment is shown on the assignment bar (10) located above the function keys. Overview of Function Keys Table 3-5 is a list of the function keys. The assignment of the function keys varies depending on the display or menu you have selected. Name Default DELETE Detail Freq Info... LCD LCD + lin/log LOAD mode Offset rms/h01 SAVE Scale scroll Set all tab/gra U/I zoom   Clear ∫ Start  Stop Table 3-5. Function Keys Function Scale axes automatically Delete configuration View details of a measured value Set frequency analysis filter View system information and version number of unit firmware Reduce brightness of display Increase brightness of display View linear/logarithmic scale Load configuration View table with harmonics Adjust zero (with cursor keys) View rms values or H01 fundamental Save configuration Adjust scales of axes (with cursor keys) Scroll through display Adopt configuration or set value for all channels View measured values in table/graph Switch between voltage channel configuration and current channel configuration (in General Setup) Adjust scales of axes (with cursor keys) View electrical work reference power or recuperated power Set electrical work integration to zero Start electrical work integration Stop electrical work integration 3-6 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145

NORMA 4000/5000
Operators Manual
3-6
Navigation through Display
1.
Use the navigation keys (6) and (27) to navigate through the display and the
menus.
The active menu item, display, or entry field in which your cursor is located is
backlit.
2.
Press Esc (26) to cancel an entry without saving or to go to the next higher menu
level.
3.
Press Enter (14) to call up a menu or to confirm an entry made in a menu.
4.
Press the measuring keys (7) and (15) to (25) to select the display mode and the
save or output functions for measured values.
The assignment of the function keys (9) varies, depending on the current menu.
The current key assignment is shown on the assignment bar (10) located above
the function keys.
Overview of Function Keys
Table 3-5 is a list of the function keys. The assignment of the function keys varies
depending on the display or menu you have selected.
Table 3-5. Function Keys
Name
Function
Default
Scale axes automatically
DELETE
Delete configuration
Detail
View details of a measured value
Freq
Set frequency analysis filter
Info…
View system information and version number of unit firmware
LCD -
Reduce brightness of display
LCD +
Increase brightness of display
lin/log
View linear/logarithmic scale
LOAD
Load configuration
mode
View table with harmonics
Offset
Adjust zero (with cursor keys)
rms/h01
View rms values or H01 fundamental
SAVE
Save configuration
Scale
Adjust scales of axes (with cursor keys)
scroll
Scroll through display
Set all
Adopt configuration or set value for all channels
tab/gra
View measured values in table/graph
U/I
Switch between voltage channel configuration and current channel
configuration (in General Setup)
zoom
Adjust scales of axes (with cursor keys)
View electrical work reference power or recuperated power
Clear
Set electrical work integration to zero
Start
Start electrical work integration
Stop
Stop electrical work integration