36" GAS RANGE INSTALLATION INSTRUCTIONS Recommended Wall Outlet Installation Locations Suggested location of the wall outlet is shown in Figure 5. The outlet may also be located in the lower corner of the adjacent cabinets, as shown in Figure 6. 3 Power Supply Cord Electrical Shock Hazard -Do not attempt to install the appliance directly to a junction box, modify the factory-installed cord, or connect a different power cord to the appliance. If the wall outlet is not sufficient to support the requirements of this appliance, it is the responsibility of the consumer to have the appropriate outlet installed by an electrician. Improper installation and electrical connections can result in electric shock, damage to the appliance, personal injury, fire, or death. 5" Max. 12.7 cm 8" 20.3 cm 7" Max. 17.8 cm WALL FLOOR Figure 5: Outlet location behind range This appliance is equipped with a 3-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. Do not, under any circumstances, cut, remove, or bypass the grounding prong. 8" (20.3 cm) 12" (30.5 cm) Figure 6: Adjacent cabinet outlet location Figure 7: Factory connected power supply cord For personal safety, the appliance must be properly grounded. For maximum safety, the power cord must be plugged into an electrical outlet that is correctly polarized and properly grounded. If a 2-prong wall receptacle is the only available outlet, it is the personal responsibility of the consumer to have it replaced with a properly grounded 3-prong wall receptacle, installed by a qualified technician. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

8
36" GAS RANGE INSTALLATION INSTRUCTIONS
Recommended Wall Outlet Installation
Locations
Suggested location of the wall outlet is shown in
Figure 5. The outlet may also be located in the lower
corner of the adjacent cabinets, as shown in Figure 6.
12”
(30.5 cm)
8”
(20.3 cm)
Figure 6: Adjacent cabinet outlet location
3
Power Supply Cord
This appliance is equipped with a 3-prong grounding plug
for your protection against shock hazard and should be
plugged directly into a properly grounded receptacle. Do
not cut or remove the grounding prong from this plug.
For personal safety, the appliance must be properly
grounded. For maximum safety, the power cord must be
plugged into an electrical outlet that is correctly polarized
and properly grounded.
If a 2-prong wall receptacle is the only available outlet,
it is the personal responsibility of the consumer to
have it replaced with a properly grounded 3-prong wall
receptacle, installed by a qualified technician.
Electrical Shock Hazard –
Do not attempt to install
the appliance directly to a junction box, modify the
factory-installed cord, or connect a different power
cord to the appliance. If the wall outlet is not sufficient
to support the requirements of this appliance, it is the
responsibility of the consumer to have the appropriate
outlet installed by an electrician. Improper installation
and electrical connections can result in electric shock,
damage to the appliance, personal injury, fire, or death.
Figure 7: Factory connected power supply cord
Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong.
Figure 5: Outlet location behind range
FLOOR
WALL
7" Max.
17.8 cm
5" Max.
12.7 cm
8"
20.3 cm