Read Sectors command protocol, X'1F7' in order to clear INTRQ interrupt signal. The Status
View all Fujitsu MHM2200AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 163 highlights
Interface words, the host should receive the relevant sector of data (512 bytes of uninsured dummy data) or release the DRQ status by resetting. Figure 5.3 shows an example of READ SECTOR(S) command protocol, and Figure 5.4 shows an example protocol for command abort. Figure 5.3 Read Sector(s) command protocol IMPORTANT For transfer of a sector of data, the host needs to read Status register (X'1F7') in order to clear INTRQ (interrupt) signal. The Status register should be read within a period from the DRQ setting by the device to 50 ms after the completion of the sector data transfer. 5-86 C141-E104-03EN
Interface
5-86
C141-E104-03EN
words, the host should receive the relevant sector of data (512 bytes of uninsured
dummy data) or release the DRQ status by resetting.
Figure 5.3 shows an example of READ SECTOR(S) command protocol, and
Figure 5.4 shows an example protocol for command abort.
Figure 5.3
Read Sector(s) command protocol
IMPORTANT
For transfer of a sector of data, the host needs to read Status register
(X’1F7’) in order to clear INTRQ (interrupt) signal. The Status
register should be read within a period from the DRQ setting by the
device to 50 ms after the completion of the sector data transfer.