Fujitsu MHM2200AT Manual/User Guide - Page 28
Environmental Specifications, Maximum Wet Bulb
View all Fujitsu MHM2200AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
1.4 Environmental Specifications Figure 1.1 Current fluctuation (Typ.) at +5V when power is turned on (5) Power on/off sequence The voltage detector circuits (the MHL Series and MHM Series) monitor +5 V. The circuits do not allow a write signal if either voltage is abnormal. These prevent data from being destroyed and eliminates the need to be concerned with the power on/off sequence. 1.4 Environmental Specifications Table 1.4 lists the environmental specifications. Table 1.4 Environmental specifications Item Temperature • Operating • Non-operating • Thermal Gradient Humidity • Operating • Non-operating • Maximum Wet Bulb Altitude (relative to sea level) • Operating • Non-operating Specification 5°C to 55°C (ambient) 5°C to 60°C (disk enclosure surface) -40°C to 65°C 20°C/h or less 8% to 90% RH (Non-condensing) 5% to 95% RH (Non-condensing) 29°C (Operating) 40°C (Non-operating) -300 to 3,000 m -300 to 12,000 m C141-E104-03EN 1-7