Ganz Security HSW-H37-4 ZN1-V4FN4 (IP Pinhole) Camera Manual - Page 15
Connections - 24
View all Ganz Security HSW-H37-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
PixelPro GXi Series 5. CONNECTIONS 1) DO DI C 1 C1 DO DO ZN1-V4FN3/FN4 Installation Guide 4) 3) 2) DI/DO terminal connector 1) Connect external input/output devices (e.g. alarm device) optionally if they are necessary. Refer to the reference below for the appropriate connections. DO (Alarm) - For connecting an external device such as relays and LEDs. Do the electrical wiring correctly referring to the following information. DO Function C Ground 1 Output Specifications 0 to 24 VDC Max load: 50mA Internal Device DO COM Relay Type Then, the connected device can be activated via its webpage. Go to "6. CONFIGURATION" for more details for its setting. 06-2014-B 15
PixelPro GXi Series
ZN1-V4FN3/FN4 Installation Guide
06-2014-B
15
5. CONNECTIONS
DI/DO terminal connector
1)
Connect external input/output devices (e.g. alarm device) optionally if they are necessary.
Refer to the reference below for the appropriate connections.
DO (Alarm)
–
For connecting an external device such as relays and LEDs.
Do the electrical wiring correctly referring to the following information.
DO
Function
Specifications
C
Ground
1
Output
0 to 24 VDC
Max load: 50mA
Then, the connected device can be activated via its webpage.
Go to
“
6. CONFIGURATION
”
for more details
for its setting.
DO
COM
Relay Type
Device
Internal
C
1
C
1
DO
DI
1)
2)
3)