Power Up and Bus Communication Power Up and Bus Communication On Concord and Advent Panels This section describes how to power up the panel and module for both new and existing installations. New Installations 1. Verify that all wiring between the panel and module is correct. 2. Connect the panel backup battery(s) and restore panel AC power. Alphanumeric touchpad displays should come on. 3. Both the green and red LEDs will turn on for one second. The green POWER LED will remain on and the red BUS LED should flash to indicate successful communication with the panel. Ìi If the green POWER LED is not on or the red BUS LED does not flash, remove AC panel power, disconnect the backup battery(s), and see Table 6 "Troubleshooting." Existing Installations Concord Panels- Same as new installation. Advent Panels- 1. Verify that all wiring between the panel and module is correct. 2. Connect the panel backup battery(s) and restore panel AC power. Alphanumeric touchpad displays should come on. 3. Press 8 for System Menu. 4. Press 0 for Program Menu. 5. Enter your Install Code (default 0123). 6. Enter Item Number 48001 to add SuperBus devices. All installed devices are automatically added (learned) into panel memory when Devices Added is indicated. 7. Press * twice to return to the Main Menu. 8. Both the green and red LEDs turn on for one second. The green POWER LED will remain on and the red BUS LED should flash to indicate successful communication with the panel. Ìi If the green POWER LED is not on or the red BUS LED does not flash, remove AC panel power, disconnect the backup battery(s), and see Table 6 "Troubleshooting." On UltraGard Panels 1. Verify that all wiring between the panel and module is correct. 2. Verify nonconflicting bus device unit number settings. 3. Connect the panel backup battery and restore panel AC power. 4. Turn on the panel AC power. 5. Set the UltraGard panel RUN/PROGRAM switch to PROGRAM. If the alphanumeric touchpad displays 1-OFF and the 1 is flashing, you must enter the 4-digit installer code to place the panel into program mode. Alphanumeric touchpads should display PROGRAM MODE and the red BUS LED on the module should be flashing continuously, indicating successful communication with the panel. Ìi If the green POWER LED is not on or the red BUS LED does not flash, set the RUN/PROGRAM switch (UltraGard) to RUN, remove AC panel power, disconnect the backup battery, and see Table 6 "Troubleshooting." 6