GE 60-803-04 Installation Instructions - Page 3
Wiring Panels, UltraGard Panels, Concord/Concord Express Panels, Advent Panels
UPC - 046188088645
View all GE 60-803-04 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Wiring Wiring Panels UltraGard Panels 1. Connect the touchpad wiring to the panel terminals as shown in Figure 3. Wire multiple touchpads in parallel. 2. If desired, connect an optional hardwire switch to the yellow touchpad wires as shown in Figure 3 (unsupervised in UltraGard systems). Note The optional touchpad hardwire input must be added to panel memory. See the UltraGard panel Installation Instructions or Reference Manual for setting the configuration. 3. Insert the touchpad wiring harness connector onto the pins located on the rear of the unit. Make sure the yellow wires are to the left. CONTROL PANEL DC BUS BUS OUT A B GND 12 13 14 15 OPTIONAL SWITCH WITH MAGNET (Not to be used in UL listed installations) Connect Shield To Earth Ground BLACK WHITE GREEN RED SHIELDED CABLE YELLOW WIRING HARNESS 49-430 NOT USED TAB SLOT(3) Concord Systems with software version 2.0 or newerWire a 2K ohm EOL resistor (49-467) in series with normally closed switches and in parallel with normally open switches (see Figure 4). Concord Systems with software versions 1.0-1.6 - This switch must be unsupervised and a resistor must not be used. Note The optional touchpad hardwire input must be added to panel memory. See the Concord/Concord Express panel Installation Instructions for setting the configuration. 3. Insert the touchpad wiring harness connector onto the pins located on the rear of the unit. Make sure the yellow wires are to the left, as shown. OPTIONAL N/O SWITCH WITH MAGNET PANEL TERMINALS +12V BUS BUS GND BUS A B 3 456 2K OHM EOL RESISTOR (Concord 2.0 or later and Concord Express panels) Connect Shield to Earth Ground WHITE GREEN RED BLACK OPTIONAL N/C SWITCH WITH MAGNET SHIELDED CABLE YELLOW NOT USED TOUCHPAD WIRING HARNESS 49-430 TAB SLOT(3) 8557148B.DS4 Figure 3. Wiring the Touchpad to UltraGard Panels Concord/Concord Express Panels 1. Connect the touchpad wiring to the panel terminals as shown in Figure 4. Wire multiple touchpads in parallel. 2. If desired, connect an optional hardwire switch to the yellow touchpad wires as shown in Figure 4. Concord Express Systems- Wire a 2K ohm EOL resistor (49-467) in series with normally closed switches and in parallel with normally open switches (see Figure 4). SuperBus® 2000 2 x 20 LCD Alphanumeric Touchpad 8557155B.DSF Figure 4. Wiring the Touchpad to Concord and Concord Express Panels Advent Panels 1. Splice the touchpad wiring to the panel SuperBus wiring harness as shown in Figure 5. Wire multiple touchpads in parallel. 2. If desired, connect an optional hardwire switch to the yellow wires on the touchpad wiring harness. Wire a 2K ohm EOL resistor (49-467) in series with normally closed switches and in parallel with normally open switches (see Figure 5). Note The optional touchpad hardwire input must be added to panel memory. See the Advent panel Installation Instructions for setting the configuration. 3