Installation Instructions 230/208 VOLT ELECTRICAL CONNECTION OPTIONS HOW TO CONNECT 1. Remove the room cabinet. 2. Connect to electrical power. 3. Review the following steps for applicable voltages. 4. Reinstall the room cabinet. supply Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TESTbutton and then the RESETbutton. If the TEST button does not trip or if the RESETbutton will not stoy engaged, discontinue use of the Zoneline and contact a qualified service technician. POWER CORD CONNECTION A power supply kit with LCDImust be used to supply power to the Zonelineunit. Theappropriate kit isdetermined by the voltage, the means of electrical connection and the amperage of the branch circuit. Power supply kit Connections of 208 or 230-volt circuits may be with (] power supply kit or (] junction box kit. All wiring, including installation of the receptacle, must be in accordance with the NECand local codes, ordinances and regulations. Codes require the use of an arc fault or leakage current detection device on the power cord except direct connect. Be sure to select the correct cord for your installation. ELECTRICAL SUBBASE CONNECTION 230/208-volt models may be installed using one of the following electrical subbases: Branch Circuit and Unit Amperage Rating 15 20 30 Proper GE Subbase Kit RAK204D15P RAK204D20P RAK204D30P* *Not approved for use on 7000 BTUmodels. Electricalsubbases provide an enclosure for direct connection or enclosed receptacles. Thesubbase kit includes the power cord. The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. Tandem 15Amp. Perpendicular 20 Amp. LargeTandem 30 Amp. 230/208-voltreceptacleconfiguration. Branch Circuit and Unit Amperage Rating 15 20 30 Proper GE Power Cord with LCDI Device RAK3153A RAK3203A RAK3303* *Not Gpproved for use on 7000 BTU models. DIRECT CONNECTION Order the following Kit for 2:30/208-volt direct connection us required: Branch Circuit and Unit Amperage Rating 15 Power Supply Accessory RAK4002A Power Supply Kit RAK4157 20 RAK4002A RAK4207 30 RAK4002A RAK4307* *Not approved for use on 7000 BTU models. Skip to the "MAKE ELECTRICALCONNECTION TO THE UNIT" section. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Installation
Instructions
230/208
VOLT ELECTRICAL CONNECTION
OPTIONS
HOW TO CONNECT
1. Remove
the
room
cabinet.
2. Connect
to electrical
power.
3. Review
the following
steps
for applicable
supply
voltages.
4. Reinstall
the
room
cabinet.
Power cords may include an arc fault interruption
or a leakage current
detection
interruption
device.
A test and reset button
is provided on the plug case
or the inline case. The device should be tested on
a periodic basis by first
pressing the TESTbutton
and then the RESETbutton.
If the TESTbutton
does
not trip or if the RESETbutton will not stoy engaged,
discontinue
use of the Zoneline and contact
a
qualified
service technician.
POWER CORD
CONNECTION
A power supplykit with LCDImust be used to supply power
to the Zonelineunit. Theappropriate kit isdetermined by
the voltage, the means of electrical connection and
the amperage of the branch circuit.
Power supply kit
Connections of 208 or 230-volt circuits may be with (]
power supply kit or (] junction box kit.
All wiring, including installation of the receptacle, must
be in accordance with the NECand local codes,
ordinances and regulations. Codes require the use of
an arc fault or leakage current detection device on the
power cord except direct connect. Be sure to select the
correct cord for your installation.
Tandem
Perpendicular
LargeTandem
15Amp.
20Amp.
30 Amp.
230/208-voltreceptacleconfiguration.
Branch
Circuit
and
Proper
GE
Power
Cord
Unit Amperage
Rating
with
LCDI Device
15
RAK3153A
20
RAK3203A
30
RAK3303*
*Not
Gpproved for use on 7000 BTU models.
ELECTRICAL SUBBASE
CONNECTION
230/208-volt
models may be installed using one
of the following electrical subbases:
Branch
Circuit
and
Proper
GE
Unit Amperage
Rating
Subbase
Kit
15
RAK204D15P
20
RAK204D20P
30
RAK204D30P*
*Not approved for use on 7000 BTUmodels.
Electricalsubbases provide an enclosure for direct
connection or enclosed receptacles. Thesubbase kit
includes the power cord.
The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is done
in accordance with these instructions and all electrical
codes.
13
DIRECT CONNECTION
Order the following
Kit for 2:30/208-volt direct
connection
us required:
Branch
Circuit
and
Power
Supply
Power
Unit Amperage
Rating
Accessory
Supply
Kit
15
RAK4002A
RAK4157
20
RAK4002A
RAK4207
30
RAK4002A
RAK4307*
*Not approved for use on 7000 BTU models.
Skip to the "MAKE ELECTRICALCONNECTION TO THE UNIT"
section.