Installation Instructions 230/208 VOLT ELECTRICAL CONNECTION OPTIONS HOW TO CONNECT 1. Remove the room cabinet. 2. Connect to electrical power. 3. Review the following steps for applicable voltages. 4. Reinstall the room cabinet. supply Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TESTbutton and then the RESETbutton. If the TEST button does not trip or if the RESETbutton will not stoy engaged, discontinue use of the Zoneline and contact a qualified service technician. POWER CORD CONNECTION A power supply kit with LCDImust be used to supply power to the Zonelineunit. Theappropriate kit isdetermined by the voltage, the means of electrical connection and the amperage of the branch circuit. Power supply kit Connections of 208 or 230-volt circuits may be with (] power supply kit or (] junction box kit. All wiring, including installation of the receptacle, must be in accordance with the NECand local codes, ordinances and regulations. Codes require the use of an arc fault or leakage current detection device on the power cord except direct connect. Be sure to select the correct cord for your installation. ELECTRICAL SUBBASE CONNECTION 230/208-volt models may be installed using one of the following electrical subbases: Branch Circuit and Unit Amperage Rating 15 20 30 Proper GE Subbase Kit RAK204D15P RAK204D20P RAK204D30P* *Not approved for use on 7000 BTUmodels. Electricalsubbases provide an enclosure for direct connection or enclosed receptacles. Thesubbase kit includes the power cord. The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. Tandem 15Amp. Perpendicular 20 Amp. LargeTandem 30 Amp. 230/208-voltreceptacleconfiguration. Branch Circuit and Unit Amperage Rating 15 20 30 Proper GE Power Cord with LCDI Device RAK3153A RAK3203A RAK3303* *Not Gpproved for use on 7000 BTU models. DIRECT CONNECTION Order the following Kit for 2:30/208-volt direct connection us required: Branch Circuit and Unit Amperage Rating 15 Power Supply Accessory RAK4002A Power Supply Kit RAK4157 20 RAK4002A RAK4207 30 RAK4002A RAK4307* *Not approved for use on 7000 BTU models. Skip to the "MAKE ELECTRICALCONNECTION TO THE UNIT" section. 13