GE AZ41E09DAB Owners Manual - Page 21
Use the Electric Heat Option. This turns off
View all GE AZ41E09DAB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
GEAppliances.com Problem The air is not always cool or hot during operation The air does not feel warm enough during heating operation The unit is not blowing out air The electric heating feature does not work Temperature display flashes Possible Causes The heat pump is not producing hot air. The Smart Fan Auxiliary Controls may be set to continuous fan. What To Do • This is normal. The heat pump will produce warm air but not as hot as air produced when the higher-cost electric heat is used. This causes the fan to blow room temperature air even when the compressor or heater cycles off. The continuous air movement provides better overall temperature control in the cool mode. See Smart Fan - Cooling/Heating on page 5. The heat pump alone produces air that feels cooler than desired. Use the Electric Heat Option. This turns off the heat pump and warms with electric heat only. NOTE: Use of this option will result in increased energy consumption. The Smart Fan Auxiliary • See Smart Fan - Cooling/Heating on page 5. Controls may be set to cycle. The power cord is not firmly attached. • Remove the room cabinet and make sure that the yellow connector on the end of the power cord is firmly engaged. The compressor may have failed. • Set the operation control to STOPand then restart the unit. If the flashing light reappears within 30 minutes, call for service. 21