GE GFW490RPKRR Installation Instructions - Page 20
Installation Instructions
View all GE GFW490RPKRR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation Instructions LOCATION OF YOUR WASHER DO NOT Install the Washer: 1. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60°F (15.6°C) for proper washer operation. 2. In an area where it will come in contact with curtains or drapes. 3. On carpet. The floor MUST be a hard surface with a maximum slope of 1/2s per foot (1.27 cm per 30 cm). To make sure the washer does not vibrate or move, you may have to reinforce the floor. NOTE: If floor is in poor condition, use 3/4s impregnated plywood sheet solidly attached to existing floor covering. IMPORTANT: Minimum Installation Clearances • When installed in alcove: Sides, Rear, Top = 0s (0 cm) • When installed in closet: Sides, Rear, Top = 0s (0 cm), Front = 1s (2.54 cm) • Consideration must be given to provide adequate clearance for installation and service. • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area. ROUGH-IN DIMENSIONS FRONT 28" (71.12cm) SIDE 54 3/8" (138.2cm) 35" (88.9cm) 39"* 46"* (99cm) (117cm) 39"* 46"* (99cm) (117cm) Built-In Pedestal™ models only *NOTE: With Legs: 40 1/2" (102.5 cm) - (3/4" (1.9 cm) adjustability) With Built-In Pedestal™: 46" (117 cm) - (3/4" (1.9 cm) adjustability) With Optional Pedestal (GFXP1308): 52" (132.1 cm) - (3/4" (1.9 cm) adjustability) Stacked: 78 1/4" (198.8 cm) 20