GE PWB7030ELES Installation Instructions - Page 11

Installation Preparation, Preparation, an Accessory Storage Drawer

Page 11 highlights

Installation Preparation Preparation WITH an Accessory Storage Drawer • PSB9120 and PWB7030 are the only approved models to be installed under 36-3/4" height with a storage drawer. CSB9120, ZSC1201, ZSC1202 and CWB7030 are not approved. • As needed, see the Standard Mount Installation Preparation OR Flush Mount Installation Preparation for configuration details. Note the modified cutout height below. • Model ZSC1202 cannot be installed with an accessory storage drawer. See installation preparation without an accessory storage drawer for this model. PREPARE THE OPENING (cont.) The Advantium/Convection 120V can be installed in combination with other GE Appliances/Monogram appliances. Always follow each product's Installation Instructions to complete the installation. Single Advantium/Convection 120V Installation: Order a 30Ǝ wide single oven cabinet or cut the opening in a wall to the dimensions shown. STANDARD MOUNT 30Ǝ 23-1/2Ǝ FLUSH MOUNT (Monogram only) 23-1/2Ǝ 25-1/4Ǝ K* Min. 21Ǝ 36-3/4Ǝ Min. Construct solid bottom - Min. 3/8" plywood supported on all four sides. Must be able to support weight of oven and contents. 22-5/8Ǝ 36-3/4Ǝ Min. Construct solid bottom - Min. 3/8" plywood supported on all four sides. Must be able to support weight of oven and contents. *See table for desired reveals on sides. Dimension 1/8" 1/4" Reveal Reveal K 30" 30-1/4" • Allow 2-1/8Ǝ case trim overlap on the sides, 1-1/16Ǝ overlap on the top and 7/8Ǝ overlap on the bottom of the opening for all models. • Oven overlaps will conceal cut edges on all sides of the opening. • When installed over a single oven or a warming drawer, allow at least 2Ǝ between the two openings. This separation will provide clearance for bottom overlap of the Advantium/Convection 120V and the other appliance overlaps. • The support must be level and rigidly mounted, flush with the bottom edge of the cutout. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

11
Installation Preparation
Preparation
WITH
an Accessory Storage Drawer
PSB9120 and PWB7030 are the only approved models to be installed under 36-3/4” height with a
storage drawer. CSB9120, ZSC1201, ZSC1202 and CWB7030 are not approved.
As needed, see the Standard Mount Installation Preparation OR Flush Mount Installation Preparation
for configuration details. Note the modified cutout height below.
Model ZSC1202 cannot be installed with an accessory storage drawer. See installation preparation
without an accessory storage drawer for this model.
STANDARD MOUNT
30
23-1/2
25-1/4
Min.
21
36-3/4
Min.
Construct
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
FLUSH MOUNT (Monogram only)
23-1/2
K*
22-5/8
36-3/4
Min.
Construct
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
PREPARE THE OPENING (cont.)
The Advantium/Convection 120V can be installed in combination with other GE Appliances/Monogram
appliances. Always follow each product’s Installation Instructions to complete the installation.
Single Advantium/Convection 120V Installation:
Order a 30 wide single oven cabinet or cut the opening in a wall to the dimensions shown.
Allow 2-1/8 case trim overlap on the sides, 1-1/16 overlap on the top and 7/8 overlap on the bottom of
the opening for all models.
Oven overlaps will conceal cut edges on all sides of the opening.
When installed over a single oven or a warming drawer, allow at least 2 between the two openings.
This separation will provide clearance for bottom overlap of the Advantium/Convection 120V and the
other appliance overlaps.
The support must be level and rigidly mounted, flush with the bottom edge of the cutout.
Dimension
1/8”
Reveal
1/4”
Reveal
K
30”
30-1/4”
*