Gigabyte G1.Sniper M5 User Manual - Page 41

D Power Control, CPU VRIN Loadline Calibration, CPU VRIN Protection, DDR CHA/B Voltage Protection

Page 41 highlights

`` 3D Power Control && CPU VRIN Loadline Calibration Allows you to set the Load-Line Calibration level for the CPU VRIN. The levels are (from highest to lowest): Extreme, Turbo, High, Medium, Low, and Standard. Selecting a higher level keeps the CPU VRIN voltage more consistent with what is set in BIOS under heavy load. Auto lets the BIOS automatically configure this setting and sets the voltage following Intel's specifications. (Default: Auto) && CPU VRIN Protection Allows you to set the over-current protection level for the CPU VRIN voltage. The adjustable range is from 150.0mV to 500.0mV. Auto lets the BIOS automatically configure this setting. (Default: Auto) && DDR CH(A/B) Voltage Protection Allows you to set the voltage limit on Channel A and Channel B memory voltage for over-voltage protection. The adjustable range is from 150.0mV to 300.0mV. Auto lets the BIOS automatically configure this setting. (Default: Auto) && CPU VRIN Current Protection Allows you to set the over-current protection level for the CPU VRIN voltage. Auto Lets BIOS automatically configure this setting. (Default) Standard~Extreme Selects Standard, Low, Medium, High, Turbo, or Extreme which represents different level of over-current protection for the CPU VRIN voltage. && DDR CH(A/B) Current Protection Allows you to set the over-current protection level for the memory voltage. Auto Lets BIOS automatically configure this setting. (Default) Standard~Extreme Selects Standard, Low, Medium, High, Turbo, or Extreme which represents different level of over-current protection for the memory voltage. - 41 - BIOS Setup

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

- 41 -
BIOS Setup
`
3D Power Control
&
CPU VRIN Loadline Calibration
Allows you to set the Load-Line Calibration level for the CPU VRIN. The levels are (from highest to lowest):
Extreme, Turbo, High, Medium, Low, and Standard. Selecting a higher level keeps the CPU VRIN voltage
more consistent with what is set in BIOS under heavy load.
Auto
lets the BIOS automatically configure
this setting and sets the voltage following Intel's specifications. (Default: Auto)
&
CPU VRIN Protection
Allows you to set the over-current protection level for the CPU VRIN voltage. The adjustable range is from
150.0mV to 500.0mV.
Auto
lets the BIOS automatically configure this setting. (Default: Auto)
&
DDR CH(A/B) Voltage Protection
Allows you to set the voltage limit on Channel A and Channel B memory voltage for over-voltage protection.
The adjustable range is from 150.0mV to 300.0mV.
Auto
lets the BIOS automatically configure this setting.
(Default: Auto)
&
CPU VRIN Current Protection
Allows you to set the over-current protection level for the CPU VRIN voltage.
±
Auto
Lets BIOS automatically configure this setting. (Default)
±
Standard~Extreme
Selects Standard, Low, Medium, High, Turbo, or Extreme which represents different
level of over-current protection for the CPU VRIN voltage.
&
DDR CH(A/B) Current Protection
Allows you to set the over-current protection level for the memory voltage.
±
Auto
Lets BIOS automatically configure this setting. (Default)
±
Standard~Extreme
Selects Standard, Low, Medium, High, Turbo, or Extreme which represents different