Haier CWH18B CWH18A Manual - Page 12

Complete Installation

Page 12 highlights

Complete Installation NOTE: Handle the air conditioner gently. 4. Reinstall the two screws that attach the cabinet to the base. 1. Make sure the free end of the ground wire is outside of the cabinet. 5. Push the front panel straight on and then lower it slightly to lock it into place. WARNING 6. Reinstall the two screws to attach the front panel to the air conditioner cabinet. Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. 2. Insert the air conditioner into cabinet. NOTE: Make sure the free end of the ground wire is outside of the cabinet. NOTE: For through-the-wall installations, if needed, install the molding around the room side of cabinet. A A. Ground wire outside of the cabinet WARNING Electrical Shock Hazard Connect green ground wire to ground screw. Failure to do so can result in death or electrical shock. 3. Connect the green ground wire to the ground screw. Position the ground wire pointing straight up. Put the excess ground wire between the coil and the air conditioner cabinet. Electrical Shock Hazard WARNING Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 7. Plug into a grounded 3 prong outlet. 8. Press RESET on the power supply cord. See "Electrical Requirements". A B A. Green ground wire B. Ground screw 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

11
Complete Installation
NOTE: Handle the air conditioner gently.
1.
Make sure the free end of the ground wire is outside of the
cabinet.
2.
Insert the air conditioner into cabinet.
NOTE: Make sure the free end of the ground wire is outside
of the cabinet.
3.
Connect the green ground wire to the ground screw.
Position the ground wire pointing straight up. Put the excess
ground wire between the coil and the air conditioner cabinet.
4.
Reinstall the two screws that attach the cabinet to the base.
5.
Push the front panel straight on and then lower it slightly to
lock it into place.
6.
Reinstall the two screws to attach the front panel to the air
conditioner cabinet.
NOTE: For through-the-wall installations, if needed, install the
molding around the room side of cabinet.
7.
Plug into a grounded 3 prong outlet.
8.
Press RESET on the power supply cord. See "Electrical
Requirements".
A. Ground wire outside of the cabinet
A. Green ground wire
B. Ground screw
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
A
WARNING
Electrical Shock Hazard
Connect green ground wire to ground screw.
Failure to do so can result in death or electrical shock.
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING