SUPER Control Used for fast cooling. The air co nditioner automatically sets fan speed to High and temperature to 64°F (18°C). NOTE: Smart System control button does not operate when RapidCool control is selected. 1. Press SUPER control. The air conditioner automatically sets fan speed to High and temperature to 64°F (18°C). SUPER 2. To turn SUPER control off, press the SUPER control button, Mode, Fan, Power or the up arrow button. Fan Speed Press FAN to select High, Med, Low or Auto. NOTE: Auto fan speed cannot be selected in Fan mode. Sleep Control NOTES: ■ If the current room temperature is 80°F (26°C) or higher, the set temperature will not change when Sleep control is activated. ■ If the current room temperature is below 80°F (26°C), the set temperature will automatically increase 2°F (1°C) during the first 2 hours after Sleep control is activated. The set temperature will not increase during the last 6 hours of Sleep control. 1. Press MODE to select Cool, Dry or Heat (Heat/Cool models only). 2. Press FAN to select High, Med or Low. 3. Press the up or down arrow button to set the temperature. 4. Press SLEEP. After 10 seconds, the lights on the control panel display will dim. The mode indicator lights will remain on. NOTE: The mode, temperature and fan speed may be adjusted during Sleep control. After 10 seconds, the lights on the control panel display will dim again. 5. To turn off Sleep control, press SLEEP again or wait 8 hours for the air conditioner to turn off automatically. NOTE: The air conditioner will return to previous settings after Sleep control is turned off. Temperature ■ Press the up arrow button to raise the temperature. Each time you press or hold the up arrow button, the temperature will go up 1°F (1°C) until it reaches 90°F (32°C). ■ Press the down arrow button to lower the temperature. Each time you press or hold the down arrow button, the temperature will go down 1°F (1°F) until it reaches 64°F (18°F). Timer To set Timer for a 30-minute to 24-hour delay before air conditioner is turned off (air conditioner must be On): 1. Press TIMER. Timer indicator light on the air conditioner control panel will flash. 2. Press up or down arrow button to change the delay time from 30 minutes to 24 hours. 3. After 5 seconds, Timer indicator light on the air conditioner control panel will remain on. To set Timer to turn on air conditioner, keeping previous settings: 1. Turn off the air conditioner. 2. Press TIMER. Timer indicator light on the air conditioner control panel will flash. 3. Press up or down arrow button to change the delay time from 30 minutes to 24 hours. 4. After 5 seconds, Timer indicator light on the air conditioner control panel will remain on. To set Timer to turn on air conditioner, changing the previous settings: 1. Turn on air conditioner. 2. Adjust the mode to Smart System control, Cool, Dry, Fan, Heat (Heat/Cool models only), SUPER control or Power Saver. 3. For Cool or Heat (Heat/Cool models only) mode: ■ Adjust fan speed to High, Med, Low or Auto. ■ Adjust temperature between 64°F and 90°F (18°C and 32°C). 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

15
SUPER Control
Used for fast cooling. The air co nditioner automatically sets fan
speed to High and temperature to 64°F (18°C).
NOTE: Smart System control button does not operate when
RapidCool control is selected.
1.
Pr
control. The air conditioner automatically
sets fan speed to High and temperature to 64°F (18°C).
2.
To turn
control off, press the
control
button, Mode, Fan, Power or the up arrow button.
Fan Speed
Press FAN to select High, Med, Low or Auto.
NOTE: Auto fan speed cannot be selected in Fan mode.
Sleep Control
NOTES:
If the current room temperature is 80°F (26°C) or higher, the
set temperature will not change when Sleep control is
activated.
If the current room temperature is below 80°F (26°C), the set
temperature will automatically increase 2°F (1°C) during the
first 2 hours after Sleep control is activated.
The set temperature will not increase during the last 6 hours
of Sleep control.
1.
Press MODE to select Cool, Dry or Heat (Heat/Cool models
only).
2.
Press FAN to select High, Med or Low.
3.
Press the up or down arrow button to set the temperature.
4.
Press SLEEP. After 10 seconds, the lights on the control
panel display will dim. The mode indicator lights will remain
on.
NOTE: The mode, temperature and fan speed may be
adjusted during Sleep control. After 10 seconds, the lights on
the control panel display will dim again.
5.
To turn off Sleep control, press SLEEP again or wait 8 hours
for the air conditioner to turn off automatically.
NOTE: The air conditioner will return to previous settings after
Sleep control is turned off.
Temperature
Press the up arrow button to raise the temperature. Each time
you press or hold the up arrow button, the temperature will go
up 1°F (1°C) until it reaches 90°F (32°C).
Press the down arrow button to lower the temperature. Each
time you press or hold the down arrow button, the
temperature will go down 1°F (1°F) until it reaches 64°F
(18°F).
Timer
To set Timer for a 30-minute to 24-hour delay before air
conditioner is turned off (air conditioner must be On):
1.
Press TIMER. Timer indicator light on the air conditioner
control panel will flash.
2.
Press up or down arrow button to change the delay time from
30 minutes to 24 hours.
3.
After 5 seconds, Timer indicator light on the air conditioner
control panel will remain on.
To set Timer to turn on air conditioner, keeping previous
settings:
1.
Turn off the air conditioner.
2.
Press TIMER. Timer indicator light on the air conditioner
control panel will flash.
3.
Press up or down arrow button to change the delay time from
30 minutes to 24 hours.
4.
After 5 seconds, Timer indicator light on the air conditioner
control panel will remain on.
To set Timer to turn on air conditioner, changing the
previous settings:
1.
Turn on air conditioner.
2.
Adjust the mode to Smart System control, Cool, Dry, Fan,
Heat (Heat/Cool models only), SUPER
control or Power
3.
For Cool or Heat (Heat/Cool models only) mode:
Adjust fan speed to High, Med, Low or Auto.
Adjust temperature between 64°F and 90°F (18°C and
32°C).
Saver.
SUPER
ess SUPER
SUPER
SUPER