Haier HWM130-9188 User Manual - Page 8
Confirm the water faucet, Connection between the water inlet hose jointer and the water faucet
View all Haier HWM130-9188 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Confirm the water faucet water faucet, suitable The exit end face of the faucet water faucet, not suitable It is required that the front end shall be longer than 10mm. The exit end face of the faucet shall be flat and smooth. If not please file it to avoid leakage. Connection between the water inlet hose jointer and the water faucet 1.Press the lower end of the lock lever and push down the slider. Take off the water inlet hose jointer from the water inlet hose component. See to Figure 1. 2 Take off the nameplate. Make sure the threading is 4mm above the upper surface of the nut. See to Figure 6 If the threading is less than 4mm above the upper surface of the nut. please loosen the screws water inlet hose jointer Slider Screw Lock level Screw knife Nameplate Bushing water inlet hose Figure 1 Figure 2 Figure 3 3 Loosen the screw till the water faucet can be accessed. Put the jointer of the water inlet hose on the faucet. See to Figure 2. (If the faucet is too large and the jointer can not be set on the water faucet, please loosen the four screws and take out the bushing in the jointer. The front end of the faucet must be smooth, otherwise it may leak water. See to Figure 3.) 4.Fasten the four screws evenly. See to Figure 4. 5 Twisting the fastening nut, See to Figure 5 After twisting, the threading is less than 2mm above the upper surface of the nut. Figure 4 Screw nut Figure 5 about 4mm after twisting About above 2mm after twisting Figure 6 6