Page 36 highlights
Disassembly/Assembly 1. Shut down power to the pump by moving the breaker supplying power to the pump to the off position. 2. Remove the screw as shown (fig 64). Remove the wiring compartment cover as shown (fig 65). Figure 64 Figure 65 Page 34
Disassembly/Assembly
1.
Shut down power to the pump by moving the breaker supplying power to the
pump to the off position.
2.
Remove the screw as shown
(fig 64).
Remove the wiring compartment cover
as shown
(fig 65).
Figure 65
Figure 64