Hayward Salt & Swim Salt & Swim Owner's Manual - Page 5

Mounting the Salt & Swim Control Box, Plumbing - salt and swim installation

Page 5 highlights

Mounting the Salt & Swim Control Box The Salt & Swim is contained in a raintight enclosure that is suitable for outdoor mounting. The Control Box must be mounted a minimum of 10 ft. (4 meters) horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell is installed. The Control Box is designed to mount vertically on a flat surface with the cables facing downward. Because the enclosure also acts as a heat sink (disperses heat from inside the box), it is important not to block the four sides of the Control Box. Do not mount Salt & Swim inside a panel or tightly enclosed area. Before securing the Control Box to the intended location, make sure that the power cord will reach the GFCI outlet and that the Cell cable will reach the location where the Cell Vessel will be installed. Use the included Mounting Template to position the fasteners to the mounting surface. Refer to the diagram below. Secure Mounting Template to desired mounting location and drill mounting holes. Screw in top fasteners leaving 1/8" space between screw head and surface U se t o mount on flat su rfa ce Useto mount on post MOUNTING TEMPLATE Use the included hardware or your own hardware (suitable fora 20lb load) to mount the Control Box to a wall or post within 3 feet of a GFCI outlet, making sure that the cord will reach. Use this templateto locateand drillfastenerholes. After ma rkin g the moun tin g surface w ith this tem pla te, scre w in t op fasten ers le aving 1/ 8" spa ce be tween screw hea d and su rfa ce Han g Control Box on fasteners S crew in b otto m fa ste ners secu rely U se t o moun t on fla t surfa ce Use to mount on post 092 xxx 1 Hang Control Box on fasteners 2 Screw in bottom fasteners securely. 3 4 Plumbing The Cell Vessel is designed to install in either 1½" or 2" PVC pool plumbing. For pools using 1½" polypipe, you must use a Hayward DIY-POLYPIPE adapter kit. The Cell Vessel must be installed on a 10" run of straight pipe at the end of the return piping just before the water returns to the pool. All pool equipment should be upstream from the Cell Vessel. It must be located within 15 feet of where the Control Box is mounted. Also, there must be enough clearance to insert and remove the Cell from the Vessel after the Vessel is installed. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

3
Mounting the Salt & Swim Control Box
Mounting the Salt & Swim Control Box
Mounting the Salt & Swim Control Box
Mounting the Salt & Swim Control Box
Mounting the Salt & Swim Control Box
The Salt & Swim is contained in a raintight enclosure that is suitable for outdoor
mounting.
The Control Box must be mounted a minimum of 10 ft. (4 meters)
horizontal distance (or more, if local codes require) from the pool, within 3ft from a
GFCI outlet, and within 15ft from where the Cell is installed.
The Control Box is designed to mount vertically on a flat surface with the cables
facing downward.
Because the enclosure also acts as a heat sink (disperses heat
from inside the box), it is important not to block the four sides of the Control Box.
Do
not mount Salt & Swim inside a panel or tightly enclosed area.
Before securing the Control Box to the intended location, make sure that the
power cord will reach the GFCI outlet and that the Cell cable will reach the location
where the Cell Vessel will be installed. Use the included Mounting Template to
position the fasteners to the mounting surface. Refer to the diagram below.
Plumbing
Plumbing
Plumbing
Plumbing
Plumbing
The Cell Vessel is designed to install in either 1½" or 2" PVC pool plumbing.
For
pools using 1½" polypipe, you must use a Hayward DIY-POLYPIPE adapter kit. The
Cell Vessel must be installed on a 10" run of straight pipe at the end of the return
piping just before the water returns to the pool.
All pool equipment should be
upstream from the Cell Vessel.
It must be located within 15 feet of where the
Control Box is mounted.
Also, there must be enough clearance to insert and
remove the Cell from the Vessel after the Vessel is installed.
Screw in top
fasteners leaving
1/8” space between
screw head and surface
Secure Mounting
Template to desired
mounting location and drill
mounting holes.
Hang Control Box
on fasteners
Screw in bottom
fasteners securely.
MOUNTING TEMPLATE
Use the included hardware or your own hardware
(suitable for a 20lb load) to mount the Control Box
to a wal l or post within 3 feet of a GFCI outlet,
making sure that the cord will reach. Use this
template to locate and drill fastener holes.
1
3
2
4