final value, continue
UPC - 082916001456
View all HP 33s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 203 highlights
Given the loop-control number ccccccc.fffii, ISG increments ccccccc to ccccccc + ii, compares the new ccccccc with fff, and makes program execution skip the next program line if this ccccccc > fff. If current value > final value, continue loop. If current value ≤ final value, continue loop. M M M M $ ! $ $ ! $ N N N N If current value ≤ final value, exit loop. If current value > final value, exit loop. For example, the loop-control number 0.050 for ISG means: start counting at zero, count up to 50, and increase the number by 1 each loop. The following program uses ISG to loop 10 times. The loop counter (0000001.01000) is stored in the variable Z. Leading and trailing zeros can be left off. Press | Z to see that the loop-control number is now 11.0100. Programming Techniques 13-19