HP AM866A Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 20 - Page 327
HIL-1305, HIL-1306, HIL-1307, HIL-1308
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 327 highlights
33 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fan(s) failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that three fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1307 Message , [HIL-1307], ,, ERROR, , Four or five fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1308 Message Probable Cause , [HIL-1308], ,, ERROR, , All fans failed. Replace failed fan FRUs immediately. Indicates that all fans have failed. This message is often preceded by a low fan speed message. Fabric OS Message Reference 275 53-1000600-02