HP AM866A Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, Apr - Page 114
BL-1020, Message, Probable Cause, Recommended, Action, systemVerification, diagPost, Severity
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
5 BL-1020 BL-1020 Message , [BL-1020], ,, CRITICAL, , Switch timed out initializing the chips. Probable Cause Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the switch. Severity CRITICAL BL-1021 Message , [BL-1021], ,, INFO, , Retry , internal port retry initialization, . Probable Cause Indicates that the switch had internal ports not online and that the system is retrying to bring the ports that failed back online. Recommended No action is required. Action Severity INFO BL-1022 Message , [BL-1022], ,, CRITICAL, , Init Failed: Switch DISABLED because internal ports were not ONLINE, . Probable Cause Indicates that the switch initiation failed because one or more of the internal ports was not online. The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. Additional fault messages precede and follow this error, providing more information. See other error messages for recommended action. If the message persists, replace the switch. Severity CRITICAL 56 Fabric OS Message Reference 53-1001157-01