32 FSPF-1005 FSPF-1005 Message , [FSPF-1005], ,, ERROR, , Wrong Section Id , should be , input port = Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID. It should be set to 0 for a nonhierarchical fabric. Brocade switches support only section ID 0. Recommended Action Use a frame analyzer to verify that the reported section ID is 0. Any connected switch from another manufacturer with a section ID other than 0 is incompatible in a fabric of SilkWorm switches. Disconnect the offending switch. Severity ERROR FSPF-1006 Message , [FSPF-1006], ,, ERROR, , FSPF Version not supported, input port = Probable Cause Indicates that the FSPF version is not supported on the specified input port. Recommended Action Update the FSPF version by running the firmwareDownload command to update the firmware to the latest version. All current versions of the Fabric OS support FSPF version 2, which is the correct version. Severity ERROR 214 Fabric OS Message Reference 53-1001157-01