HP AM866A Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, Apr - Page 562
Swch-1011
![]() |
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 562 highlights
81 SWCH-1011 Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = ). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING 504 Fabric OS Message Reference 53-1001157-01
![](/manual_guide/products/hewlettpackard-ae370a-brocade-fabric-os-message-reference-guide-v620-53100115701-2009-0184d26/562.png)
504
Fabric OS Message Reference
53-1001157-01
SWCH-1011
81
Severity
WARNING
SWCH-1011
Message
<timestamp>, [SWCH-1011], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support Trunk Area
functionality. (active ver = <active SWC version>, Trunk Area enabled on switch =
<'1' if Trunk Area ports exist; Otherwise '0'>).
Probable Cause
Indicates the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.
Recommended
Action
Load a firmware version on standby that supports Trunk Area functionality, using the
firmwareDownload
command.
Severity
WARNING