Replace the HP BladeSystem c7000 OA tray, Remove both Onboard Administrators.
UPC - 883585668663
View all HP BL260c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Step Step 4 Step 5 Step 6 Step 7 Onboard Administrator errors action and verification Action Reseat the OA tray: 1 Remove both Onboard Administrators. 2 Reseat the OA tray. 3 Install both Onboard Administrators in their original locations in the OA tray. Verification Wait until the the Insight Display indicates that the Onboard Administrators have completed power-on tests. If the active Onboard Administrator operates properly, then the repair is complete. If the symptoms still exist, then continue to the next step. Action Replace the HP BladeSystem c7000 OA tray: 1 Remove both Onboard Administrators. 2 Remove the OA tray. 3 Install a new OA tray. 4 Install both Onboard Administrators in the original locations in the OA tray. Verification Wait until the Onboard Administrators complete all power-on tests. If the symptoms no longer exist, then the repair is complete. If the symptoms still exist, then continue to step 8. Action If the Active LED is illuminated on the left HP BladeSystem c3000 Onboard Administrator (OA1), then reseat the Onboard Administrator (OA1 module is the suspect Onboard Administrator). If the Active LED is illuminated on the right HP BladeSystem c3000 Onboard Administrator (OA2), then reseat the OA tray (OA2 module is the suspect Onboard Administrator): 1 Remove all Onboard Administrators installed in the OA tray. 2 Reseat the OA tray. 3 Install all Onboard Administrators in their original locations in the OA tray. Verification Wait until the Insight Display indicates that the second or non-suspect Onboard Administrator has completed power-on tests. If the second or non-suspect HP BladeSystem c3000 OA operates properly, then replace the suspect Onboard Administrator and continue with step 9. If the second or non-suspect OA has the same issue as the suspect OA, and the suspect OA is OA1, then continue to the next step. Action Reseat the OA tray: 1 Remove all Onboard Administrators from the OA tray. 2 Reseat the OA tray. 3 Install all Onboard Administrators in their original locations. Enclosure troubleshooting 48