HP BL260c HP BladeSystem c-Class Enclosure Troubleshooting Guide - Page 51
Interconnect module errors action and verification, Remove all Onboard Administrators.
UPC - 883585668663
View all HP BL260c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Step Step 3 Step 4 Step 5 Step 6 Interconnect module errors action and verification Action Remove the interconnect module and install a known-working interconnect module. Verification If the interconnect module health LED is green, then the repair is complete. If the interconnect module health LED remains off, then the original interconnect module is not causing the error. Replace the original interconnect module: 1 Remove the interconnect module. 2 Install the original interconnect module. 3 Continue to the next step. Action If troubleshooting an HP BladeSystem c7000 Enclosure, perform the following substeps: 1 Remove all Onboard Administrators. 2 Reseat the OA tray. 3 Install all Onboard Administrators in their original OA bays. If troubleshooting an HP BladeSystem c3000 Enclosure, reseat the Onboard Administrator. Verification If the interconnect module health LED is green, then the connection is restored. The repair is complete. If the interconnect module health LED is off, then continue to the next step. Action Remove the suspect Onboard Administrator and install a known-working Onboard Administrator. Verification If the interconnect module health LED is green, then the Onboard Administrator failed. The repair is complete. If the interconnect module health LED is off, then the suspect Onboard Administrator is not causing the error. • If troubleshooting an HP BladeSystem c7000 Enclosure, then continue to the next step. • If troubleshooting an HP BladeSystem c3000 Enclosure, then continue to step 7. Action Replace the OA tray: 1 Remove all Onboard Administrators. 2 Remove the OA tray. 3 Install an known-working OA tray. 4 Install all Onboard Administrators in their original OA bays. Verification If the interconnect module health LED is green, then the OA tray failed. The repair is complete. If the interconnect module health LED is off, then continue to the next step. Enclosure troubleshooting 51