• Description: Sets the date of the enclosure with the following definitions: o MM: Month o DD: Day o hh: Hour (24-hour time) o mm: Minute o CC: Century o YY: Year o TZ: Time zone If you leave the time zone variable blank, then the current time zone is left in effect. • Access level/Bay level: OA administrator, OA operator • Restrictions: Date and time can only be set if NTP is disabled. MM is an integer from 01 to 12. DD is an integer from 01 to 31. hh is an integer from 00 to 24. mm is an integer from 00 to 60. For valid time zones, see "Time Zone settings (on page 169)". SET DISPLAY EVENTS • Command: SET DISPLAY EVENTS {ON | OFF} • Description: o Turns the displaying of events that are triggered by status changes in the system on or off. o This command is specific to the CLI session, and must be issued for every CLI session to display events in that session. • Access level/Bay level: All • Restrictions: Only for bays for which you have privileges SET ENCLOSURE ASSET • Command: SET ENCLOSURE ASSET [TAG] "" • Description: o Sets the enclosure asset tag o The default enclosure asset tag is blank Enclosure management commands 103
![](/manual_guide/products/hewlettpackard-bl480c-hp-bladesystem-onboard-administrator-command-line-interface-user-guide-version-300-b350cfc/103.png)