= 776 Interconnect Bay Power Summary: Bay Name 1 GbE2c Ethernet Blade Switch 2 Cisco Catalyst Blade Switch 312 Power Allocated (Watts DC 25 40 ------= 65 Fan Power Summary: Total Fans Fan Rule (Number of Fans) (Number of Fans) 6 6 Present Power (Watts DC 153 Power Allocated (Watts DC 480 >SHOW ENCLOSURE STATUS Enclosure: Status: Degraded Unit Identification LED: On Diagnostic Status: Internal Data OK Onboard Administrator: Status: OK Power Subsystem: Status: Degraded Power Mode: Redundant Redundancy State: Redundancy Lost Power Capacity: 1321 Watts DC Present Power: 716 Watts AC Cooling Subsystem: Status: OK Fans Good/Wanted/Needed: 6/6/5 Fan 1: 10010 RPM (56%) Fan 2: 7810 RPM (43%) Fan 3: 10012 RPM (56%) Fan 4: 10013 RPM (56%) Fan 5: 7814 RPM (43%) Fan 6: 10002 RPM (56%) >SHOW ENCLOSURE TEMP Locale Bay # Temp Status Enclosure OK Onboard Administrator 1 OK Blade Bay 1 N/A Blade Bay 2 N/A Blade Bay 4 N/A Interconnect Module 1 OK Interconnect Module 2 OK >SHOW ENCRYPTION Temp -------23C/ 73F 25C/ 77F 20C/ 68F 23C/ 73F 20C/ 68F ------- Caution ------- 40C 75C 38C 40C 38C ----- Critical -------- 45C 80C 43C 45C 43C ----- ENCRYPTION mode is NORMAL >SHOW OA INFO Onboard Administrator #1 information: Product Name : BladeSystem c3000 Onboard Administrator General management commands 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183

General management commands 54
=
776
Interconnect Bay Power Summary:
Bay
Name
Power Allocated (Watts DC)
---
--------------------------------
--------------------------
1
GbE2c Ethernet Blade Switch
25
2
Cisco Catalyst Blade Switch 312
40
-------
=
65
Fan Power Summary:
Total Fans
Fan Rule
Present Power
Power Allocated
(Number of Fans)
(Number of Fans)
(Watts DC)
(Watts DC)
----------------
----------------
--------------
---------------
6
6
153
480
>SHOW ENCLOSURE STATUS
Enclosure:
Status: Degraded
Unit Identification LED: On
Diagnostic Status:
Internal Data
OK
Onboard Administrator:
Status: OK
Power Subsystem:
Status: Degraded
Power Mode: Redundant
Redundancy State: Redundancy Lost
Power Capacity: 1321 Watts DC
Present Power:
716 Watts AC
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 6/6/5
Fan 1:
10010 RPM (56%)
Fan 2:
7810 RPM (43%)
Fan 3:
10012 RPM (56%)
Fan 4:
10013 RPM (56%)
Fan 5:
7814 RPM (43%)
Fan 6:
10002 RPM (56%)
>SHOW ENCLOSURE TEMP
Locale
Bay # Temp Status
Temp
Caution
Critical
---------------------- ----- -----------
--------
-------
--------
Enclosure
OK
23C/ 73F
40C
45C
Onboard Administrator
1
OK
25C/ 77F
75C
80C
Blade Bay
1
N/A
20C/ 68F
38C
43C
Blade Bay
2
N/A
23C/ 73F
40C
45C
Blade Bay
4
N/A
20C/ 68F
38C
43C
Interconnect Module
1
OK
----
---
---
Interconnect Module
2
OK
----
---
---
>SHOW ENCRYPTION
ENCRYPTION mode is NORMAL
>SHOW OA INFO
Onboard Administrator #1 information:
Product Name