HP BL480c HP BladeSystem Onboard Administrator Command Line Interface User Gui - Page 142

Poweron Interconnect, Restart Interconnect, Set Interconnect Powerdelay

Page 142 highlights

Sends a request to power off the interconnect module • Access level/Bay level: Administrator, operator Bay specific • Restrictions: You must have explicit access to a bay given by the ASSIGN INTERCONNECT command. POWERON INTERCONNECT • Command: POWERON INTERCONNECT {ALL | ]} • Description: Powers on the specified interconnect • Access level/Bay level: Administrator, operator Bay specific • Restrictions: You must have explicit access to a bay given by the ASSIGN INTERCONNECT command. RESTART INTERCONNECT • Command: RESTART INTERCONNECT • Description: Resets the interconnect tray in the specified bay • Access level/Bay level: Administrator, operator Bay specific • Restrictions: You must have explicit access to a bay given by the ASSIGN INTERCONNECT command. SET INTERCONNECT POWERDELAY • Command: SET INTERCONNECT POWERDELAY {ALL | ]} {number of seconds to delay power | NOPOWERON} • Description: Sets the PowerDelay status for the specified interconnect or range of interconnects. If the delay is zero, the delay has no effect on the device. If the delay is NOPOWERON, the device cannot power on until all devices have completed their delays. Interconnect management commands 142

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183

Interconnect management commands 142
Sends a request to power off the interconnect module
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the
ASSIGN INTERCONNECT
command.
POWERON INTERCONNECT
Command:
POWERON INTERCONNECT {ALL | <bay number> [{ - | , } <bay number>]}
Description:
Powers on the specified interconnect
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the
ASSIGN INTERCONNECT
command.
RESTART INTERCONNECT
Command:
RESTART INTERCONNECT <bay number>
Description:
Resets the interconnect tray in the specified bay
Access level/Bay level:
Administrator, operator
Bay specific
Restrictions:
You must have explicit access to a bay given by the
ASSIGN INTERCONNECT
command.
SET INTERCONNECT POWERDELAY
Command:
SET INTERCONNECT POWERDELAY {ALL | <bay number> [{ - | , } <bay
number>]} {number of seconds to delay power | NOPOWERON}
Description:
Sets the PowerDelay status for the specified interconnect or range of interconnects. If the delay is
zero, the delay has no effect on the device. If the delay is NOPOWERON, the device cannot power
on until all devices have completed their delays.