HP BL480c HP ProLiant BL480c Server Blade User Guide - Page 9

System board components

Page 9 highlights

Online/activity LED Fault/UID LED (green) (amber/blue) Off Steadily amber Off Amber, flashing regularly (1 Hz) Off Off Interpretation A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. System board components Item Description 1 Processor socket 1 (populated) 2 System board thumbscrew 3 Processor socket 2 4 Bezel LED connector 5 Hard drive backplane connector 6 System battery 7 System maintenance switch (SW3) 8 Embedded NICs 9 Mezzanine connector 2 (Type I or Type II mezzanine) 10 Enclosure connector 1 11 Mezzanine connector 1 (Type I mezzanine only) 12 System board thumbscrew 13 Mezzanine connector 3 (Type I or Type II mezzanine) 14 Enclosure connector 2 15 System board thumbscrew 16 FBDIMM slots (1-12) Component identification 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Component identification 9
Online/activity LED
(green)
Fault/UID LED
(amber/blue)
Interpretation
Off
Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
Off
The drive is offline, a spare, or not configured as part of an
array.
System board components
Item
Description
1
Processor socket 1 (populated)
2
System board thumbscrew
3
Processor socket 2
4
Bezel LED connector
5
Hard drive backplane connector
6
System battery
7
System maintenance switch (SW3)
8
Embedded NICs
9
Mezzanine connector 2 (Type I or Type II mezzanine)
10
Enclosure connector 1
11
Mezzanine connector 1 (Type I mezzanine only)
12
System board thumbscrew
13
Mezzanine connector 3 (Type I or Type II mezzanine)
14
Enclosure connector 2
15
System board thumbscrew
16
FBDIMM slots (1-12)