HP BladeSystem bc2000 Setup and Installation Guide HP BladeSystem bc2000 and b - Page 65
POST Error Messages
View all HP BladeSystem bc2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
C POST Error Messages Use POST error messages to assist in troubleshooting and performing basic diagnostic functions. POST error messages represent what the BIOS reports. The following table lists the numeric codes and text messages specific to blade PCs. For information about troubleshooting, see Troubleshooting on page 62. NOTE: Attempt the recommended actions in the order in which they are listed. If the first does not resolve the issue, try the next on the list. POST Error Messages Code/Message 101-Option ROM Checksum Error Health LED Red 102/103-System Board Failure Red 162-System Options Not Set Amber 163-Time & Date Not Set 164-Memory Size Error Amber Amber 201-Memory Error Red Possible Cause Recommended Action Blade system board has failed. ● Clear CMOS. ● Flash the system ROM. ● Replace the blade PC. Blade PC system board has failed. ● Clear CMOS ● Replace the blade PC. CMOS was cleared or ● the blade PC's battery has failed. ● Reset the system time and date in Computer Setup (F10). Replace the blade PC's RTC battery. CMOS was cleared Memory configuration is incorrect. Reset the system time and date in Computer Setup (F10). ● Ensure the SODIMM(s) are properly installed. ● Verify that the proper type of SODIMM is installed. ● Reseat the SODIMM(s). ● Replace the SODIMM(s). ● Replace the blade PC. An SODIMM may not ● Ensure the SODIMM(s) are properly be seated correctly or installed. is bad. ● Verify that the proper type of SODIMM is installed. ● Reseat the SODIMM(s). ENWW 57