HP Cluster Platform Interconnects v2010 Windows GridStack Troubleshooting Quic - Page 2

System Tools

Page 2 highlights

• WSD patch from Windows web site: http://support.microsoft.com/?kbid=910481 • Make sure to download the correct patch file according to your OS. build (32bit or 64bit) • Stability problem will occur when WSD patch not installed 1. How to query the windows OS system information? • From the Windows desktop choose ◊ Start menu ◊ All programs ◊ Accessories ◊ System Tools ◊ System Information • To export the system information from to a text file chooses export option from file menu, assign a file name and save. 2. How to check what is the firmware version on HCA using vstat and flint: • Use the vstat.exe utility to verify the HCA status and firmware version. • Use the Flint.exe utility to check the HCA type • The vstat.exe and Flint.exe utilities are located under \Program Files (x86)\Voltaire\WinIB\bin> for 64-bit machines, and \Program Files\Voltaire\WinIB\bin> for 32-bit machines. o Flint.exe utility To run flint.exe run the following commands from command line - mst status (Will display the HCA reading devices that are available) - Flint -d mt23100_pciconf0 q (will read the information from the HCA - Look at the board ID for HCA type identification o vstat.exe utility

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

WSD patch from Windows web site:
Make sure to download the correct patch file according to your OS.
build (32bit or 64bit)
Stability problem will occur when WSD patch not installed
1.
How to query the windows OS system information?
From the Windows desktop choose
Start menu
All programs
Accessories
System Tools
System Information
To export the system information from to a text file chooses export option
from file menu, assign a file name and save.
2.
How to check what is the firmware version on HCA using vstat and
flint:
Use the
vstat.exe
utility to verify the HCA status and firmware version.
Use the
Flint.exe
utility to check the HCA type
The
vstat.exe and Flint.exe
utilities are located under \Program Files
(x86)\Voltaire\WinIB\bin> for 64-bit machines, and \Program
Files\Voltaire\WinIB\bin> for 32-bit machines.
o
Flint.exe
utility
To run flint.exe run the following commands from command line
-
mst status
(Will display the HCA reading devices that are
available)
-
Flint –d mt23100_pciconf0 q
(will read the information from the
HCA
-
Look at the board ID for HCA type identification
o
vstat.exe utility