Bad Block Replacement BBR performed on a disk, when there is a disk group hardware problem
![]() |
View all HP EVA P6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
If an event occurs that causes a second resynchronization while the upgrade resynchronization is still in progress, the controller will terminate with a code of 0b 08 01 00. The following events cause the controller to resysnchronize automatically: • Initialization of the array • Debug flags set through the command line interface or P6000 Control Panel • Disk group hardware problem on a Vraid1 virtual disk, or attempted reconnection of a disk when there is a disk group hardware problem • Bad Block Replacement (BBR) performed on a disk Every effort should be made to ensure that these events do not occur during the upgrade process. If controller termination occurs due to multiple resynchronizations, contact your HP-authorized service representative for assistance. 72 Troubleshooting
![](/manual_guide/products/hewlettpackard-eva-p6000-hp-enterprise-virtual-array-updating-product-software-guide-xcs10001000-56971229-2011-b5f1d59/72.png)