HP High Availability FC Disk Array 30/FC User Guide - Page 221
²&xuuhqw²5hylvlrqv²
View all HP High Availability FC Disk Array 30/FC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 221 highlights
Menu item List Update Option Current Revisions File Selection Instructions Controller Firmware Disk Firmware Property Description N/A Lists SP microcode and disk module firmware revisions currently in use (Figure 7-7). N/A N/A Download, update PROM and restart controllers Download and restart controllers Download only Reports the file previously specified using the Select File option on the File menu. Lists basic instructions for Firmware Update Tool use. Downloads microcode to the SCSI disk array's database drives, burns PROM code contained in the download file into the SP's PROMs, and restarts the SP using the new microcode. Downloads microcode to the SCSI disk array's database drives and restarts the SP using the new microcode. Downloads microcode to the SCSI disk array's database drives, but does not take effect until the SPs are restarted (with a Restart Controllers only command, or by power cycling the SCSI disk array). Restart Restarts the SPs, using microcode residing on the controllers only database drives. N/A Supplies firmware to all compatible disk modules within the SCSI disk array (that is, those with the same product ID). This applies even to disk modules owned by another SP. The firmware then resides permanently within those disk modules until another disk module firmware update is performed. 7-20