HP High Availability FC Disk Array 30/FC User Guide - Page 308
Troubleshooting, Event code, Description, Recommended threshold
View all HP High Availability FC Disk Array 30/FC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 308 highlights
Event code 0x68E 0x68F 0x690 0x691 0x692 0x693 0x694 0x695 0x696 Description Inconsistent Stripe. Inconsistent write or time stamp were detected in a RAID group. Inconsistent Time Stamps. Inconsistent time stamps were detected in a RAID group on a verify. Drive Failed. A drive was shut down. Checksum Error on Device read. A checksum error was detected on a read from an individual disk. There was no data transfer involved. Incoherent Stripe. Data and parity were not consistent in a RAID group. Uncorrectable Stripe. Inconsistent write or time stamps could not be corrected in RAID group. Parity Invalidated. Parity has been invalidated in a RAID group. Uncorrectable Sector. An uncorrectable sector was detected on a RAID-1 mirrored pair. Mirror Sector Invalidated. A sector on a RAID-1 mirrored pair was invalidated on a rebuild. Event code 0x801 0x802 0x803 0x804 Description Recommended threshold Soft SCSI error. This code indicates that an abnormal SCSI bus or disk drive event was detected. A retry of the operation cleared the condition. Notify the user after 25 errors/day/ FRU. Illegal SCSI Bus interrupt. An inconsistent interrupt situation has been detected on the controller. Notify the user after 10 errors/month/ FRU. Recommend Disk Replacement. IBM only. Single Bit Error. The SP's tolerance level for single bit errors in the write cache has been exceeded. Troubleshooting 8-35