HP Indigo 7800 Leak Valves Flow Calibration -- CA393-08710 Rev 01 - Page 7

HP Indigo 7800 Manual

Page 7 highlights

8. Load 90 gsm gloss substrate into the feeder drawers 2 and 3. 9. In the FDT, go to the Air pressure calibration area to set the parameters and perform the calibration. Figure 2-5 FDT - Air pressure calibration area a. In the GSM drop-down list, select the substrate weight 090. b. In the Drawer field, enter a drawer number (either 2 or 3). c. Click Vacuum and view the measurement results on the voltmeter. Figure 2-6 Measuring voltage Calibrating the flow of the vacuum leak valve 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

8.
Load 90 gsm gloss substrate into the feeder drawers 2 and 3.
9.
In the FDT, go to the
Air pressure calibration area
to set the parameters and perform the calibration.
Figure 2-5
FDT — Air pressure calibration area
a.
In the
GSM
drop-down list, select the substrate weight
090
.
b.
In the
Drawer
field, enter a drawer number (either 2 or 3).
c.
Click
Vacuum
and view the measurement results on the voltmeter.
Figure 2-6
Measuring voltage
Calibrating the flow of the vacuum leak valve