HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 43

Fan failed in designated Bulk Power Supply. Probable Cause: Fan failure or fan

Page 43 highlights

Event ID Event Severity 7786 Warning 7791 Warning 7793 Warning 7795 Warning 7796 Warning 7798 Warning 7799 Error 7803 Error 7806 Warning 7822 Error 7823 Error 7824 Warning Event Description AC power to the PDCA was removed. Data Byte 3 specifies PDCA number. Probable Cause: Power source supplying AC to the PDCA has failed. Recommended Action: Troubleshoot AC power problem. WBEM EventID: 653. WBEM ProviderName: FPL_IndicationProvider. Cabinet Main Blower Failed. Probable Cause: Cabinet Blower Failed Recommended Action: Replace failed blower module as soon as possible following the Blower Module Remove and Replace Procedures. WBEM EventID: 654. WBEM ProviderName: FPL_IndicationProvider. 48 Volt Converter Failed. Data Byte 3 specifies PDCA number. Probable Cause: The PDCA identified has failed. This will be evident by many BPS_FAIL codes and probably a AC_DELETED code in the Event Log. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 655. WBEM ProviderName: FPL_IndicationProvider. Fan failed in designated Bulk Power Supply. Probable Cause: Fan failure or fan obstructed Recommended Action: If fan is obstructed, remove obstruction. If no obstruction, Contact HP Support personnel to troubleshoot problem. WBEM EventID: 657. WBEM ProviderName: FPL_IndicationProvider. 1 Side Converter Over Temp. Probable Cause: If this code is not accompanied by other codes pointing to the same Bulk Power Supply, then it is an internal component failure. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2436. WBEM ProviderName: FPL_IndicationProvider. Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to the cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus entity has become functional, providing previously missing power consumption information. Recommended Action: Purchase and install a Bulk Power Supply, if redundancy is desired. WBEM EventID: 659. WBEM ProviderName: FPL_IndicationProvider. +48V DC has exceeded its upper limit. Probable Cause: The cabinet's 48V power has exceeded an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 660. WBEM ProviderName: FPL_IndicationProv +48V DC has fallen below its lower limit. Probable Cause: The cabinet's 48V power has fallen below an acceptable lower threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 661. WBEM ProviderName: FPL_Indica Cabinet Fan Failed. Probable Cause: Cabinet Fan Failed Recommended Action: Replace failed cabinet fan module as soon as possible following the Cabinet Fan Module Remove and Replace Procedures. WBEM EventID: 662. WBEM ProviderName: FPL_IndicationProvider. Housekeeping power has exceeded expected levels. Probable Cause: The cabinet's housekeeping power has risen above an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 670. WBEM ProviderName: FPL_IndicationProvider. Housekeeping power has fallen below expected levels. Probable Cause: The cabinet's housekeeping power has fallen below an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 671. WBEM ProviderName: FPL_IndicationProvider. The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number. Probable Cause: The BPS are installed in an illegal configuration. Recommended Action: Re-configure the BPS in a manner consistent with the explanation in the Problem Description statement. WBEM EventID: 672. WBEM ProviderName: FPL_IndicationProvider. Platform Events 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
AC power to the PDCA was removed. Data Byte 3 specifies PDCA number. Probable
Cause: Power source supplying AC to the PDCA has failed. Recommended Action:
Troubleshoot AC power problem. WBEM EventID: 653. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7786
Cabinet Main Blower Failed. Probable Cause: Cabinet Blower Failed Recommended
Action: Replace failed blower module as soon as possible following the Blower
Module Remove and Replace Procedures. WBEM EventID: 654. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7791
48 Volt Converter Failed. Data Byte 3 specifies PDCA number. Probable Cause: The
PDCA identified has failed. This will be evident by many BPS_FAIL codes and
probably a AC_DELETED code in the Event Log. Recommended Action: Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 655. WBEM
ProviderName: FPL_IndicationProvider.
Warning
7793
Fan failed in designated Bulk Power Supply. Probable Cause: Fan failure or fan
obstructed Recommended Action: If fan is obstructed, remove obstruction. If no
obstruction, Contact HP Support personnel to troubleshoot problem. WBEM EventID:
657. WBEM ProviderName: FPL_IndicationProvider.
Warning
7795
1 Side Converter Over Temp. Probable Cause: If this code is not accompanied by
other codes pointing to the same Bulk Power Supply, then it is an internal component
failure. Recommended Action: Contact HP Support personnel to troubleshoot
problem. WBEM EventID: 2436. WBEM ProviderName: FPL_IndicationProvider.
Warning
7796
Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to the
cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus
entity has become functional, providing previously missing power consumption
information. Recommended Action: Purchase and install a Bulk Power Supply, if
redundancy is desired. WBEM EventID: 659. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7798
+48V DC has exceeded its upper limit. Probable Cause: The cabinet's 48V power has
exceeded an acceptable upper threshold. Recommended Action: Contact HP Support
personnel to troubleshoot problem. WBEM EventID: 660. WBEM ProviderName:
FPL_IndicationProv
Error
7799
+48V DC has fallen below its lower limit. Probable Cause: The cabinet's 48V power
has fallen below an acceptable lower threshold. Recommended Action: Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 661. WBEM
ProviderName: FPL_Indica
Error
7803
Cabinet Fan Failed. Probable Cause: Cabinet Fan Failed Recommended Action:
Replace failed cabinet fan module as soon as possible following the Cabinet Fan
Module Remove and Replace Procedures. WBEM EventID: 662. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7806
Housekeeping power has exceeded expected levels. Probable Cause: The cabinet's
housekeeping power has risen above an acceptable upper threshold. Recommended
Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID:
670. WBEM ProviderName: FPL_IndicationProvider.
Error
7822
Housekeeping power has fallen below expected levels. Probable Cause: The cabinet's
housekeeping power has fallen below an acceptable upper threshold. Recommended
Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID:
671. WBEM ProviderName: FPL_IndicationProvider.
Error
7823
The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number.
Probable Cause: The BPS are installed in an illegal configuration. Recommended
Action: Re-configure the BPS in a manner consistent with the explanation in the
Problem Description statement. WBEM EventID: 672. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7824
Platform Events
43