HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 90
IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Event ID Event Severity 11531 Warning 11537 Warning 11538 Warning 11566 Error 11567 Error 11568 Error 11569 Error 11575 Error 11576 Error 11578 Error 11579 Error Event Description The fPar has been enabled to boot, and contains at least one CPU and adequate memory but has not been given any IO resources. It must be reconfigured and reset before it may boot an operating system. Probable Cause: The fPar has been enabled to boot, and contains at least one CPU and adequate memory but has not been given any IO resources. The soft partition (fPar) may therefore only boot as far as the EFI shell. It must be reconfigured and reset before it may boot an operating system. Recommended Action: Reconfigure the soft partition using an Operating-system-specific utility then reset the soft partition. WBEM EventID: 4932. WBEM ProviderName: FPL_IndicationProvider. All processors are scheduled for deconfiguration. Probable Cause: All CPUs were scheduled to be deconfigured through a combination of user deconfigures and/or failures Recommended Action: No action is required. WBEM EventID: 5270. WBEM ProviderName: FPL_IndicationProvider. Processors have been reconfigured due to installation of a new processor type, or SFW revision change. Probable Cause: Either all CPUs were slated for deconfiguration, or NVM has been cleared, or a new CPU type has been installed. Recommended Action: No action is required. WBEM EventID: 5262. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 3.3V power fault. Probable Cause: One of the 3.3v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6825. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 5.0V power fault. Probable Cause: One of the 5.0v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6826. WBEM ProviderName: FPL_IndicationProvider. IO Backplane -12V power fault. Probable Cause: One of the -12v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6827. WBEM ProviderName: FPL_IndicationProvider. IO Backplane +12V power fault. Probable Cause: One of the +12v VRM's is reporting a fault. One failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6828. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 1.5V temperature fault. Probable Cause: One of the 1.5v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6829. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 3.3V temperature fault. Probable Cause: One of the 3.3v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6830. WBEM ProviderName: FPL_IndicationProvider. IO Backplane -12.0V temperature fault. Probable Cause: One of the -12v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6831. WBEM ProviderName: FPL_IndicationProvider. IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is over temp and has shutdown. One failure and the Redundancy state is 'not redundant', after two power faults the redundancy state is 'insufficient'. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6832. WBEM ProviderName: FPL_IndicationProvider. 90 WBEM Provider Event Tables