HP Integrity rx8640 Site Preparation Guide, Fourth Edition - HP Integrity rx86 - Page 38
Environmental Temperature Sensor, Non-Operating Environment, Cooling, Internal Chassis Cooling
![]() |
View all HP Integrity rx8640 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 2-9 Example ASHRAE Thermal Report (continued) ASHRAE class Condition Minimum configuration Full configuration Typical configuration 1 cell board, 2 CPUs, 2 GB, 1 core I/O card 4 cell boards, 16 CPUs, 128 GB, 2 core I/O cards, 16 I/O cards, 4 hard disks 2 cell boards, 8 CPUs, 64 GB, 1 core I/O card, 8 I/O cards, 2 hard disks Environmental Temperature Sensor To ensure that the system is operating within the published limits, the ambient operating temperature is measured using a sensor placed on the server backplane. Data from the sensor is used to control the fan speed and to initiate system overtemp shutdown. Non-Operating Environment The system is designed to withstand ambient temperatures between -40° C to 70° C under non-operating conditions. Cooling Internal Chassis Cooling The cabinet incorporates front-to-back airflow across the system backplane. Nine 120-mm fans mounted externally on the front chassis wall behind the cosmetic front bezel push air into the unit. Twelve 120-mm fans housed in cosmetic plastic fan carriers and mounted externally to the rear chassis wall pull air through the unit. Each fan is controlled by a smart fan control board embedded in the fan module plastic housing. The smart fan control board receives fan control input from the system fan controller on the system backplane and returns fan status information to the system fan controller. The smart fan control board also controls the power and the pulse width modulated control signal to the fan and monitors the speed indicator back from the fan. The fan status LED is driven by the smart fan control board. Bulk Power Supply Cooling Cooling for the bulk power supplies (BPS) is provided by two 60-mm fans contained within each BPS. Air flows into the front of the BPS and is exhausted out of the top of the power supply though upward facing vents near the rear of the supply. The air is then ducted out of the rear of the chassis. PCI/Mass Storage Section Cooling Six 92-mm fans located between the mass storage devices and the PCI card cage provide airflow through these devices. The PCI fans are powered off of housekeeping power and run at full speed at all times. The air is pulled through the mass storage devices and pushed through the PCI card cage. Separation is provided between the PCI bulkheads to allow adequate exhaust ventilation and to help reduce the localized airflow dead spots that typically occur at the faceplate tail of each PCI card. Standby Cooling Several components within the chassis consume significant amounts of power while the system is in standby mode. The system fans will run at a portion of full speed during standby to remove 38 System Specifications
![](/manual_guide/products/hewlettpackard-rp8440-site-preparation-guide-edition-hp-integrity-rx8640-hp-9000-rp8440-servers-f94ec86/38.png)