HP LH4r HP Netserver LH 3 NetRAID Installation Guide

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 1
    cluster supported HP NetServers and the cluster software, and references the Shared Storage Supplement for installation and setup of the shared storage. • Shared Storage Supplement - This supplement is specific to the shared storage device you are using and must be used with the installation guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 2
    Supplies specification. See Versions in the Configuration Guide for details. Updated the pdf to include the latest version of the HP NetServer Microsoft Cluster Installation Guide. This later version incorporates technical, grammatical and format changes along with adding installation instructions
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 3
    HP NetServer LH 3 with NetRAID (HP Rack Storage/8) Cluster Configuration Guide 14 July 1998 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LH 3 configurations for Microsoft Cluster Server. These configurations minimize single points of
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 4
    System software: Navigator version Operating System Service pack L.10.00 or later Microsoft Windows NT Server 4.0, Enterprise Edition or later SP4 or later SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: HP NetServer LH3 350 or 400 MHz.
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 5
    Logical disks Configuration options: Cabinet Model No. of cabinets Disk drives: RAID arrays Cables LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot 1 per RAID array 6 maximum per NetRAID adapter Cluster mode on (cache write-through) Ultra SCSI disabled BIOS disabled Set any other
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 6
    Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH 3 and HP Rack Storage/8s. Only these cabling configurations and cables are supported. HP Microsoft Cluster Server with One HP NetRAID Adapter 4
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 7
    HP Microsoft Cluster Server Power Cabling 5
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 8
    Versions 14 July 1999 22 June 1999 18 November 1998 Revised No. of Power Supplies specification from "2 - 3" to "2 required, 3 for redundancy." In System Software changed from "SP3 with hotfix or later" to "SP4 or later". This revision does not impact performance and does not require updating
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 9
    HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement Rack Storage/12FC Rack Storage/12 Rack Storage/8 Storage System/6 HP AutoRAID Disk Array Model 12H or HP A3661B Model 30/FC High Availability Disk Array 23 June 1999
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 10
    This page intentionally left blank. HP NetServer Installation Guide 2
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 11
    for errors contained of its software on equipment that reviewed for familiarization with safety markings and instructions used in this manual: • Microsoft and Server Division 10955 Tantau Avenue Cupertino, CA 95014-0770, USA © Copyright 1999, Hewlett-Packard Company HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 12
    LH 4 (WITH FIBRE CHANNEL) ...21 LPR...23 LPR (WITH NETRAID LOCAL AND SHARED STORAGE 25 LX/LXR PRO ...27 LXR 8000 ...28 INSTALL SERVICE PACK FOR ALL HP NETSERVERS 30 6 SHARED STORAGE SOFTWARE SETUP 31 SHARED STORAGE SETUP ...31 CREATE THE ARRAY FILE SYSTEMS...31 7 MICROSOFT CLUSTER SERVER SOFTWARE
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 13
    HP NetServers, set up, assemble and cable the cluster, and install server and cluster software. NOTE This installation guide is incomplete without the supplement specific to your shared storage system. When directed by this guide, turn to the supplement to get the necessary instructions. Version
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 14
    A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here can cause unnecessary work and unpredictable results. HP NetServer Installation Guide 6
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 15
    Windows NT, version 4.0 and Service Pack (SP). See the Configuration Guide for your cluster solution for the applicable Windows NT and SP versions and Microsoft Cluster Server installation software. NOTE Some HP NetServers, as stated in part "5 NetServer Software Setup," require installing Windows
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 16
    Guide for your cluster. • Cluster Installation Test. Downloaded from the Certified Installer Corner under Install & Configure on the HP NetServer Clustering Solutions web site. • NIC drivers. Download HP drivers from Software Downloads page under Install & Configure" on the HP NetServer
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 17
    to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 18
    3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 10
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 19
    with the system and instructions in the shared storage supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack Assistant program. If not, see HP NetServers web site to download this program. Connect the LAN Adapters Two sets of LAN adapters need to be
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 20
    a procedure specific to your HP NetServer as listed below. Secondly, you will install the applicable Service Pack on the NetServer. Select your procedure from the following list: You will... First Second Go to procedure for... LCII LC3 LH Pro LH 3 LH 3 (with NetRAID local storage) LH 4 LH 4 (Fibre
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 21
    addresses and Intra-cluster LAN IP addresses must be on different subnets. LC3 Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 22
    time. NOTE The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different subnets. LH Pro 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 23
    HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Select User Preferences and then the LH4 Integrated NetRAID setting you want to use. If you are using NetRAID for shared storage, disable the LH4 Integrated HP NetRAID
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 24
    1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 25
    complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Using the Setup Utility disable the LH3 Integrated NetRAID. Integrated NetRAID
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 26
    detection and manually specify the mass storage drivers: 3. Load drivers using the NT 4.0 Drivers floppy disk you created in step 13 above (page 18). • Load the driver for the device you want to boot from. This will be the HP NetRAID Adapter Driver. • Load the IDE driver, since the CD drive is on
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 27
    HP NetServer Navigator CD in the CD-ROM drive and restart the server. 8. During reboot enter the Setup Utility by pressing F2. 9. Select User Preferences and then the LH4 Integrated NetRAID setting you want to use. If you are using NetRAID for shared storage, disable the LH4 Integrated HP NetRAID
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 28
    in the LH 4 internal bays this will normally be the embedded SCSI Symbios driver. • Secondly, load the IDE driver, since the CD drive is on the IDE bus. • Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage do not load the HP NetRAID driver at this
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 29
    is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Select User Preferences and then the LH4 Integrated NetRAID
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 30
    LH 4 internal bays this will normally be the embedded SCSI Symbios driver or embedded NetRAID. • Secondly, load the IDE driver, since the CD drive is on the IDE bus. • Finally, load any other mass storage drivers you need. If you are using the Fibre Channel HBA for shared storage do not load the HP
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 31
    . The intra-cluster LAN should be set to 100 Mbps. Do not use the Auto setting. Part "6 Shared Storage Software Setup" in the Shared Storage Supplement and start with Install Fibre Channel HBA Driver. LPr These procedures provide instructions for servers using NetRAID and AutoRAID shared storage
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 32
    Symbios driver on the drivers disk. Select "SCSI Symbios driver for the HP NetServer LPr." • Secondly, load the IDE driver, since the CD drive is on the IDE bus. • Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage do not load the HP NetRAID driver at
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 33
    Library. Select NetRAID Assistant for WindowsNT and Windows95 from the list and then the Execute button. Follow the instructions to create the NetRAID Assistant installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2. HP NetServer Installation Guide 25
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 34
    server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: 3. Load drivers using the NetRAID-3Si Cluster Firmware and Driver intra-cluster LAN should be set to 100 Mbps. Do not use the Auto setting. HP NetServer Installation Guide 26
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 35
    down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is a newer version, choose Continue and go
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 36
    These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 37
    , select Properties then Settings and set the network speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN should be set to 100 Mbps. Do not use the Auto setting. HP NetServer Installation Guide 29
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 38
    Service Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service Pack (SP3 or SP4). Do not install the Hot Fix associated with Service Pack 3 at this time. NOTE Do not install the Microsoft Cluster Server Software
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 39
    you identified. An example display follows: NOTE Disk Administrator lists disks in order, beginning with local (non-shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 31
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 40
    the capacity would be one-half the capacity of the two drives. 3. Click OK to include the full disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide 32
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 41
    Disk Administrator, Partitioned Disk Array NOTE Do not partition a disk into separate drives. Microsoft Cluster Server Software will only manage one partition per disk. 4. Repeat steps 1 through 3 assigned the next sequential letter to the disk array. HP NetServer Installation Guide 33
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 42
    Drive Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 43
    box to select one of the arrays that you just partitioned and assigned a drive letter. Disk Administrator highlights the selected disk. 2. From the Disk Administrator's field type a label (name) for the drive. Choose a descriptive label such as "Shared Drive X.". HP NetServer Installation Guide 35
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 44
    . 6. Repeat steps 1 through 5 to format each drive to be shared in the cluster. The following example depicts both drives formatted with permanent drive letters assigned. Disk Administrator, Formatting and Assigning Volume labels 7. Exit Disk Administrator. HP NetServer Installation Guide 36
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 45
    CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of System B. 2. Run the Microsoft Cluster Server setup program. Setup.exe Cluster Server software setup of System A. Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 37
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 46
    the LAN adapter according to use (for example, intra-cluster LAN). When you enable cluster use setup gives you three options: • Use for all communications Choose this option if you are configuring a client LAN adapter, and System A and B reside on the same IP subnet. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 47
    configured all LAN adapters, click Next. 11. Setup lists your LAN adapters and asks you to prioritize them for internal communications between nodes. Move the Intra-cluster LAN to the top of the list so it has the highest priority. See the example dialog below. HP NetServer Installation Guide 39
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 48
    specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System A. Reboot System A. 16. To finish installation of the Microsoft Cluster Server, leave System A running, go to the next procedure and install MSCS on System B. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 49
    not already downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide 41
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 50
    integrity download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 51
    NetRAID Supplement to HP NetServer Microsoft Cluster Installation Guide 8 March 1999
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 52
    only supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. Version History Date 8 March 99 Change Revised to add instructions for HP Rack Storage/12. NetRAID Supplement to the HP NetServer
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 53
    the HP NetServers Microsoft Cluster Installation Guide. VERSION HISTORY...2 1 WHAT'S NEEDED ...4 SOFTWARE...4 NEED MORE HELP?...4 OBTAIN HP NETRAID UTILITIES ...4 2 NETSERVER HARDWARE SETUP ...6 3 SHARED STORAGE HARDWARE SETUP 7 HP RACK STORAGE/12 SETUP...7 HP RACK STORAGE/8 SETUP...8 HP STORAGE
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 54
    to unpack the archive. • Follow the instructions in the readme.txt file to create the installation floppy disk. Label the floppy disk NetRAID-3Si Cluster Firmware and Driver then go to part 2 "NetServer Hardware Setup." NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 4
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 55
    Floppy Disk NR Cluster Firmware and Driver HP NetRAID Assistant 1 HP NetRAID Assistant 2 7. Label three blank formatted floppy disks as listed. 8. Copy the contents of each subdirectory to the appropriate floppy disk. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 5
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 56
    PCI slots specified by the HP NetServer Configuration Guide for your cluster configuration. 2. Make sure that previously installed adapters are in the correct PCI slots. NOTE For clusters using HP NetRAID adapters, typically, only one is provided (installed) in the server for management of shared
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 57
    ) in each Rack Storage/12. Follow the instructions supplied with the Controller for installation. to part "4 Cluster Cabling and Setup" in the Installation Guide or setup another share storage device such as the Rack Storage/8. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 58
    When cabled as a single bus unit, the HP Rack Storage/8 provides up to 8 hard disk drives on a single SCSI bus. Although the HP Rack Storage/8 are shipped from the factory Cluster Cabling and Setup" in the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 59
    Interior Before connecting the disks housed in the HP Storage System/6, set up the internal cables to support the cluster. To gain access proceed as chassis. HP Storage System/6 Cabinet with Bezel and Side Cover Removed NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 9
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 60
    Verify and Reconnect Internal Cabling Using the schematic view of the HP Storage System/6's internal cabling shown below, check and if necessary, external connector 5182-9326 Storage System/6 Cabinet Internal Cabling NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 10
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 61
    A or B at this time. You must configure the HP NetRAID Adapter and install Microsoft Windows NT Server, Enterprise Edition before attaching the shared storage unit. to part "4 Cluster Setup and Cabling" of the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 62
    usability and safety standards. Power Down Shared Storage If Shared Storage power is on, make sure that it is turned off before continuing. to part "5 NetServer Software Setup of the Installation Guide" NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 63
    5 NetServer Software Setup This part of the supplement is intentionally left blank. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 13
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 64
    the system. 3. The system will boot to DOS and run the HP NetRAID firmware flash utility. Follow the instructions to update the firmware on all NetRAID-3Si adapters. When complete, cycle power on the system to reboot. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 14
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 65
    8. Exit HP NetRAID Express Tools when all adapters have been configured. 9. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 15
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 66
    10. Exit HP NetRAID Express Tools when all adapters have been configured. 11. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 16
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 67
    system log during reboot. The entry is: Event ID: Source: Type: Description: 4 mraidnt Error Driver detect an internal error in its data structure for. This is a spurious event and may be ignored. No error occurred. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 17
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 68
    Thru, the NetRAID Assistant will not configure the array. After setting RAID levels as stated below return to "Create the Array File Systems" in part "6 Shared Storage Software Setup" of the Installation Guide. Set RAID Levels on a Cluster Use these instructions to set up HP NetServer cluster RAID
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 69
    1 array consists of two drives that contain exactly the same data. That is, all of the data on one drive is replicated (mirrored) on the other. Since each drive contains a complete copy of all data, all data is still NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 19
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 70
    simply copied from the good drive to the new drive. The following table shows how data is distributed: Raid Level 1 Data Distribution Stripe Drive 1 Drive 2 1 Block 1 2 steps 3 and 4 to define identical arrays. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 20
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 71
    loss in storage capacity. With RAID 5 the equivalent of only one hard drive in the array is used for redundancy. The following table shows how 1 2 Block 2.1 Parity 2 Block 2.2 3 Parity 3 Block 3.1 Block 3.2 NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 21
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 72
    defined, its parameters must be set. 1. Click Next. The wizard displays its Logical Drive Definition window. 2. This window shows the array's RAID level and its usable size displayed and useable storage capacity for the NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 22
  • HP LH4r | HP Netserver LH 3 NetRAID Installation Guide - Page 73
    C(N-1), where N is the number of drives and C is the capacity of one drive. 3. Click Advanced and set the Write HP NetRAID Initialization may be time consuming. 2. When initialization is complete, exit HP NetRAID Assistant. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

Microsoft Cluster Installation
Documentation
To assist you in installing your HP NetServer Microsoft Cluster, this file contains three
separate documents combined into one pdf file.
Configuration Guide
- This guide provides configuration information specific to your
cluster configuration that you will need during the installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two
documents used to install the cluster.
It covers the installation of all cluster supported
HP NetServers and the cluster software, and references the Shared Storage Supplement
for installation and setup of the shared storage.
Shared Storage Supplement
- This supplement is specific to the shared storage device
you are using and must be used with the installation guide.
It provides instructions for
installing and setting up your shared storage devices.
14 July 1999
(See next page)