HP LH4r HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 6

Storage - netserver lh4

Page 6 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage HP NetServer LH4 400, 450, 500, 550 MHz. or higher 2 - 4 4.06.22 PS or later Any size 256 MB minimum. Must be HP. 3 required, 4 for redundancy See Local Storage below. P1 - Host Bus Adapter P2 - HP TopTools Remote Control card D6028A (optional) P3 - Client LAN P4 - Intra-cluster (Heartbeat) LANs Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May Use - Embedded RAID, NetRAID-3Si, or any manufacturer or driver in any available I/O slot May Not Use - NetRAID-1 or NetRAID-3 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver SPU I/O slot RAID level Cabinet RAID arrays No. of cabinets FC Array Cards Model No. of cards/cabinet Firmware Status SCSI ID Disk SCSI IDs Disk drives: (Required) HP D8602A 1 1.12 or later P1 0, 1, 3, 5, or 0 & 1 Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 D5990A 1 - Simplex (Supplied with Rack Storage/12FC.) 2 - Duplex (Additional card required in the Rack Storage/12FC.) 4.64-00 or later 5 (fixed) 0 - 3, 8 - 15 (fixed) HP 9.1 GB Ultra SCSI Disk Module D6106A 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

2
SPU
Model
HP NetServer LH4
Clock speed
400, 450, 500, 550 MHz. or higher
No. of CPUs
2 – 4
BIOS version
4.06.22 PS or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3 required, 4 for redundancy
Local storage
See
Local Storage
below.
I/O slots:
P1 – Host Bus Adapter
P2 – HP TopTools Remote Control card D6028A (optional)
P3 – Client LAN
P4 – Intra-cluster (Heartbeat)
LANs
Storage
Local
Controller
May Use
- Embedded RAID, NetRAID-3Si, or any manufacturer or
driver in any available I/O slot
May Not Use
- NetRAID-1 or NetRAID-3
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
(Required)
Host Bus Adapter
Model
HP D8602A
No. of HBAs
1
Driver
1.12 or later
SPU I/O slot
P1
RAID level
0, 1, 3, 5, or 0 & 1
Cabinet
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards
Model
D5990A
No. of cards/cabinet
1 - Simplex (Supplied with Rack Storage/12FC.)
2 - Duplex (Additional card required in the Rack Storage/12FC.)
Firmware
4.64-00 or later
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)
Disk drives:
HP 9.1 GB Ultra SCSI Disk Module D6106A