HP LH4r HP Netserver LXr Pro8 Memory Board

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 1
    HP NetServer LXr Pro8 4 GB Memory Board Installation Guide HP Part Number 5967-2103 Printed in January 1998
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 2
    Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard Company. Hewlett-Packard Company Network Server Division Technical Marketing/MS 53U-FJ 5301 Stevens
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 3
    Contents Preface ...1 Purpose of this Guide 1 Contents of this Guide 1 Intended Audience 1 Related Documentation 2 1 Introduction 3 Errors 26 Troubleshooting Resources 27 4 Service and Support 29 U.S. and Canada 29 Europe...30 Asia/Pacific 31 Other Countries 31 Ordering HP Cables, Drive
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 4
    6 Specifications 37 7 Regulatory Information 39 Index ...41 iv
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 5
    an HP NetServer LXr Pro8. Contents of this Guide This guide includes the following topics: • Installation instructions • Troubleshooting information, from common installation problems to special steps that may help you identify and interpret errors and/or failures • International service and support
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 6
    Preface Related Documentation The following documents describe the HP NetServer LXr Pro8: • The HP NetServer LXr Pro8 User Guide • The Product and Service Reference Labels • Information Assistant on the HP NetServer Navigator CD-ROM 2
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 7
    box should include: • The 4 GB memory board • The anti-static container in which the 4 GB memory board is packaged • The HP NetServer LXr Pro8 4 GB Memory Board Installation Guide CAUTION Whenever you handle the 4 GB memory board, you should do so in an anti-static environment. Grasp the board by
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 8
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 9
    4 GB Memory Board This chapter includes guidelines and instructions for: • Powering down the NetServer • Removing the existing 4 GB memory board for the 4 GB memory board • Powering up the system Installation Basics The HP NetServer LXr Pro8 accepts up to two memory boards. Each board has 32 DIMM
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 10
    Chapter 2 Installing Memory in the 4 GB Memory Board • The memory board DIMM slots are numbered from M0 to M31 as shown in Figure 2-1. • The recommended memory configurations and the slot numbers where SDRAM DIMMs are installed are listed in Figure 2-2 and Figure 2-3. Add SDRAM DIMMs only in
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 11
    Chapter 2 Installing Memory in the 4 GB Memory Board Figure 2-2 shows memory configurations when one 4 GB Memory board is installed. Figure 2-3 shows configurations when two 4 GB memory boards are installed. The Figures show the recommended order in which DIMM slots are filled as you add 128 MB
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 12
    installation of accessories: • Number 1 Phillips head screwdriver • An anti-static service kit (3M™ 8501/8502/8503 or equivalent). This kit includes a shut down all networking software, applications, and the operating system. 3. Press the DC power switch on the HP NetServer's control panel (Figure
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 13
    by turning it clockwise (Figure 2-5). The switch turns off DC power to the HP NetServer, and also unlocks the satellite chassis. See the HP NetServer LXr Pro8 User Guide for more details on opening and closing the HP NetServer chassis. NOTE After you unlock the power interlock switch, DC power is
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 14
    Panel Accessing the Lower Board Cage The lower board cage holds the NetServer's memory boards. To reach these boards, you extend the satellite chassis and remove the lower fan module and rear access panel. NOTE If the server is mounted in a rack, cables most likely run from the satellite chassis
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 15
    grasp the two ejector handles on the HP NetServer's rear panel. Pull both handles down firmly, and then pull the satellite toward you. Pull it out until its slides are fully extended. The slides lock in the extended position, so that the satellite cannot move while you service it (Figure 2-7). 11
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 16
    Chapter 2 Installing Memory in the 4 GB Memory Board Ejector Handles Figure 2-7. Sliding Out the Satellite Chassis 2. Remove the lower fan module, as shown in Figure 2-8: a. Grasp the handles on either end of the fan module and push them toward each other. b. While continuing to push on the
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 17
    Memory in the 4 GB Memory Board Base Chassis Satellite Chassis Handles Lower Fan Module Figure 2-8. Removing the Lower Fan Module 3. Remove the NetServer's rear access panel, as shown in Figure 2-9: a. Loosen the three captive screws that fix the panel in place. b. Lift the panel straight
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 18
    Chapter 2 Installing Memory in the 4 GB Memory Board Captive Screws Rear Access Panel Figure 2-9. Removing the Rear Access Panel 14
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 19
    Chapter 2 Installing Memory in the 4 GB Memory Board Removing the Existing 4 GB Memory Board The HP NetServer has one 4 GB memory board installed. Follow these steps to remove the existing memory board for a memory upgrade: 1. After removing the rear access panel, locate
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 20
    in a slot on the 4 GB memory board. CAUTION Use only 128 SDRAM DIMMs acquired from HP. Contact HP Customer Support for a list of qualified 128 MB SDRAM DIMMs. HP will not support configurations that use non-HP SDRAM DIMMs. 1. If you are installing a new memory board, remove the 4 GB memory board
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 21
    Chapter 2 Installing Memory in the 4 GB Memory Board 4. Locate the slot where you will install the 128 SDRAM DIMM, and spread the two DIMM retaining clips outward. (Figure 2-12). Retaining Clip Retaining Clip Figure 2-12. Installing a DIMM Module 5. Align the notches on the SDRAM DIMM with the
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 22
    to replace a defective DIMM. Always downsize memory to the next lower memory configuration listed in Figure 2-2 or Figure 2-3. Memory modules are installed in specific DIMM slots for each memory configuration. You must remove SDRAM DIMMs so that the remaining memory is installed in the correct DIMM
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 23
    configuration for the downsized memory. (See Figure 2-2.) CAUTION Close all retaining clips on the 4 GB memory board before inserting it into your NetServer. This includes clips on empty slots as well as those on slots containing DIMMs. This facilitates insertion of the memory board. 10. Install
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 24
    Chapter 2 Installing Memory in the 4 GB Memory Board 3. Being careful not to touch board components, ease the first memory board into the top memory board slot and close the retaining latches on the front of the memory board to seat it snugly (Figure 2-13). Base Chassis Satellite Chassis Memory
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 25
    onto the mounting rails until it clicks into place. 7. Reattach the satellite chassis to the base chassis: a. When you finish servicing the HP NetServer, move to the front of the server and unlatch all four power supplies. (If the front bezel is in place, remove it.) b. At the rear, insert the
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 26
    The system will now power up. Ensure the indicator lights come up correctly. See "Power Supply Indicators" in the HP NetServer LXr Pro8 User Guide. NOTE The interlock switch locks the satellite chassis in place. As a safety precaution, the server cannot power up unless this switch is locked. 22
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 27
    Chapter 2 Installing Memory in the 4 GB Memory Board The HP NetServer cannot start unless the Power Interlock Switch is in this position Figure 2-15. Power Interlock Switch, HP NetServer Rear Panel 4. Turn on the monitor. 23
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 28
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 29
    are reported on the screen for specified error conditions. The errors are logged in the Error Message Utility (EMU) and/or the Error Log Report Utility (ELRU)  part of the NetServer Utilities package on the HP NetServer Navigator CD-ROM. If you have booted from the HP Navigator CD-ROM, the EMU is
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 30
    Chapter 3 Troubleshooting Standard BIOS Error Messages Several different situations generate visual or auditory error messages which appear . Appropriate POST error codes will be generated. After the first boot, the errors will not be displayed. • Mixed DIMM speed. HP only supports DIMMs running at
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 31
    problem. Troubleshooting Resources If you are having problems installing your 4 GB Memory board, a number of different tools help to troubleshoot the problem: • HP NetServer LXr Pro8 User Guide • HP NetServer Navigator CD-ROM ◊ HP NetServer Information Assistant List of Error Messages and Beep Error
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 32
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 33
    to the "Troubleshooting" chapter for the steps to follow before calling for service. Prior to calling for support, record this information: • product model name and number • product serial number • applicable error messages from system or diagnostics • applicable hardware driver revision levels
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 34
    Europe For hardware repair or telephone support in Europe, contact either: • Participating Service Authorized HP Personal Computer Reseller or • HP Customer Support Center (Netherlands) for the following countries: Austria: Belgium (Dutch): Belgium (French): Denmark: Finland: France: Germany
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 35
    Chapter 4 Service and Support Asia/Pacific For hardware service and telephone support, contact either: • A participating Reseller or • HP Customer Support Center: Australia: China: Hong Kong: India: Indonesia: Japan: Korea: Malaysia: New Zealand: Philippines: Singapore: Taiwan: Thailand: +61 (03
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 36
    from HP, such as the HP NetServer Product Line Service Handbook. Service information and reference documents, such as the Dealer Configuration File Creation Guide (CFG), are also available in Information Assistant on the HP NetServer Navigator CD-ROM. NOTE Please note that sales and support for
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 37
    Hewlett-Packard, check your local telephone directory for the HP Sales and Service Office near you. If you cannot locate an HP office, contact one of the Worldwide HP Marketing Headquarters listed here: NOTE Please note that sales and support for this Hewlett-Packard product may not be currently
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 38
    Chapter 4 Service and Support Joining CompuServe To open a CompuServe account or to obtain information on access numbers and charges in your country, you can purchase a CompuServe startup kit at a computer software reseller or you can contact CompuServe directly. Mention "Representative 133" to
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 39
    by the original end-user purchaser. Once installed in an HP NetServer, this accessory may carry the longer of either a one-year warranty or the remainder of the warranty period for the NetServer in which it is installed. This accessory may be serviced through expedited part shipments. In this event
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 40
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 41
    and +5 volts. Power Dissipation +3.3 V 77.6 W +5.0 V 10 W Environmental Environment Temperature Non-operating Operating Humidity Non-operating Operating Altitude Non-operating Operating Specification -40° C to 70° C 5° C to 35° C 5% to 95% 20% to 80% 40,000 feet (pressure altitude) 10,000 feet
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 42
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 43
    Name: Network Server Model Number(s): Product Options: HP NetServer LXr Pro8 and LXr Pro8 CTO mod 0 All conforms to the following Product Specifications: Safety: IEC contact: European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department ZQ / Standards
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 44
  • HP LH4r | HP Netserver LXr Pro8 Memory Board - Page 45
    the Memory Board, 19 L LXr Pro8 NetServer systems, 1 M Memory capacity, 1 Mixing DIMM sizes and speeds, 26 R Readme File, 3 Removing a 128 MB SDRAM DIMM Module, 18 S Standard BIOS Errors, 26 T Troubleshooting Diagnostics Overview, 25 Troubleshooting Resources, 27 W Warranty Information, 35 41
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

HP NetServer LXr Pro8
4 GB Memory Board
Installation Guide
HP Part Number 5967-2103
Printed in January 1998